Page 912 - 5G Basics - Core Network Aspects
P. 912

2                                                 Transport aspects


                                   Table 12-15 – FTU-R CLR message SPar(2) bit definitions

              ITU-T G.994.1 SPar(2) bit                       Definition of SPar(2) bit

             Number of SOC symbol   Always set to ZERO.
             repetitions (RS)
             Number of DS           Always set to ZERO.
             initialization data
             symbols (sds)
             Downstream RMC offset   Always set to ZERO
             CD time out            If set to ZERO, indicates that the FTU-R supports only the default CD_time_out_1 value
                                    of ten seconds and the CD_time_out_2 value of twenty seconds. If set to ONE, indicates
                                    that the FTU-R supports valid CD_time_out_1 values and valid CD_time_out_2 values in
                                    addition to the default value, as indicated in the corresponding CD time out 1 and CD
                                    time out 2 NPar(3) fields.




                                   Table 12-16 – FTU-R CLR message NPar(3) bit definitions



              ITU-T G.994.1 SPar(2) bit                       Definition of NPar(3) bits
             Profiles               Each valid profile is represented by one bit in a field of six bits. The valid profiles are:
                                    106a, 106b and 212a. Each profile supported by the FTU-R is indicated by setting its
                                    corresponding bit to ONE (Note).
             Duration of Channel    This 8-bit field indicates the minimum duration of the Channel Discovery 1-1 stage
             Discovery 1-1          expressed in multiple of 8 192 symbol periods with cyclic extension requested by the
                                    FTU-R. The valid values are from 1 to 16. The FTU-O shall round up the time to the
                                    nearest superframe.
             CE length multiplier   Each bit of this 9-bit field represents a CE length multiplier m, excluding the default
                                    value 10 (see clause 10.4.4). For each CE length multiplier that the FTU-R supports, the
                                    corresponding bit shall be set to ONE.
             Number of symbol       Each bit of this 6-bit field represents an MF value other than 36; specifically bit 1 shall
             periods in TDD frame    be set to ONE indicating the FTU-R supports the MF value 23. Other bits in this 6-bit
                                    field are reserved by ITU-T and shall be set to ZERO.

             CD time out 1          This 3-bit field shall be coded as an unsigned integer n=7, indicating that the maximum
                                    CD_time_out_1 value supported by the FTU-R equals forty seconds.
             CD time out 2          This 3-bit field shall be coded as an unsigned integer n=7, indicating that the maximum
                                    CD_time_out_2 value supported by the FTU-R equals eighty seconds.
             NOTE – A list of the profiles supported by the FTU-R is available in the DPU-MIB as FTUR_PROFILES inventory information.























            902