Page 1041 - 5G Basics - Core Network Aspects
P. 1041

Transport aspects                                              2


            X.6.9   Channel initialization policy for DTA

            The channel initialization policy for DTA shall be as specified in clause 12.3.7, except for the following two
            constraints:
            1)      ETR ≥ ETR_min_eoc, where
                    a)  For the purpose of verifying that ETR ≥ ETR_min_eoc, the ETR shall be calculated as defined in
                        clause X.6.8.3.3, however using the data symbol rate corresponding to the value of  hs_Mds
                        instead of the values DTA_min_Mds and DTA_max_Mds.
                    b)  The  ETR_min_eoc  calculation  shall  be  done  as  described  in  Table  9-21.  ETR_min  might  be
                        different from DTA_ETR_min.
                        NOTE – This implies that for the purpose of verifying that ETR ≥ ETR_min_eoc, the ETR and ETR_min_eoc
                        are calculated as if DTA were disabled, i.e., Mds = hs_Mds.
            2)      NDR ≤ NDR_max, where
                    a)  The NDR for the downstream direction shall be calculated using the value Mds = DTA_max_Mds
                        (see clause X.6.7.4).
                    b)  The  NDR  for  the  upstream  direction  shall  be  calculated  using  the  value  DTA_min_Mds
                        (see clause X.6.7.3).

                    c)  The  NDR_max  shall  be  replaced  with  the  value  determined  by  the  control  parameter
                        DTA_NDR_max (see clause X.6.7.5).

            X.6.10  High_BER event for DTA

            The High_BER event for DTA shall be as specified in clause 12.1.4.3.4, except for the definition of the ETR,
            which  for  DTA,  and  for  the  purpose  of  verifying  that  ETR  ≥  ETR_min_eoc,  shall  be  as  described  in
            clause X.6.9.

            X.6.11  RMC commands
            RMC commands for use with DTA are shown in Table X.4.


                                                Table X.4 – RMC commands

               Command name        Command ID                Description/comments               Reference

             DTA update          1316             Indicates a request for DTA update. May be   See Table X.4.1
                                                  included in any downstream RMC message.



                                 Table X.4.1 – DTA update command (sent by the FTU-O only)

                      Field name                 Format                           Description
             Command header              1 byte: [00 aaaaaa]     aaaaaa = 1316

             Number of downstream        1 byte: [00 aaaaaa]     aaaaaa = the updated number of downstream
             symbol periods (Mds)                                symbol periods in the TDD frame, represented as an
                                                                 unsigned integer.
             DTA frame down count        1 byte: [0000 aaaa]     aaaa = The logical frame down count to
             (DTAFDC)                                            implemention of the DTA update, represented as an
                                                                 unsigned integer.


            X.7     Initialization messages
            X.7.1   ITU-T G.994.1 Handshake phase

            This clause describes the ITU-T G.994.1 message fields specific to Annex X operation and their usage. See
            also clause 12.3.2.


                                                                                                        1031
   1036   1037   1038   1039   1040   1041   1042   1043   1044   1045   1046