2                                                 Transport aspects


            from  the  FTU-R  according  to  the  new  Mds  value  with  an  US  RMC  symbol  at  the  correct  position.  This
            completes the DTA update procedure.

            The  FTU-O  may  continue  sending  the  'DTA  update'  RMC  command  with  the  updated  Mds  value  and
            DTAFDC=0 in the following frames, until a new request to update the Mds is received from the DRA.

            The FTU-O shall not initiate a new DTA update procedure until the current update procedure has been
            completed.

            X.6.7   Transceiver related DTA control parameters
            The following control parameters facilitate DTA and Annex X operation on transceiver level:
            •       Annex X operation mode (Annex_X_mode);

            •       DTA allowed (DTA_allowed);
            •       Handshake Mds (hs_Mds);
            •       Minimum Mds for DTA (DTA_min_Mds);
            •       Maximum Mds for DTA (DTA_max_Mds);
            •       Maximum net data rate for DTA (DTA_NDR_max);

            •       Maximum net data rate (NDR_max);
            •       Minimum expected throughput (ETR_min).
            Some of the parameters specified in this section are DRA control parameters (see Annex T) that are also
            used by the FTUs.

            X.6.7.1    Annex X operation mode (Annex_X_mode)
            The control parameter Annex_X_mode is used to control the activation of Annex X operation.
            This parameter has 3 valid values:

            0:      AnnexX_FORBIDDEN:  Operation  according  to  Annex  X  is  not  allowed.  Annex  X  operation  mode
                    shall  not  be  selected  during  the  handshake  phase  of  initialization.  In  this  case  the  "Annex  X
                    operation" bit in the FTU-O CL message NPar(2) (see Table X.5) shall be set to ZERO.
            1:      AnnexX_PREFERRED: Operation according to Annex X is preferred. Annex X operation mode shall
                    be selected during the handshake phase of initialization if and only if both FTUs support Annex X
                    operation mode and they share a common profile. In this case the "Annex X operation" bit in the
                    FTU-O  CL message  NPar(2)  (see Table  X.5)  shall  be set  to  ZERO  if  the  FTU-O does  not  support
                    operation according to Annex X and shall be set to ONE if the FTU-O supports operation according
                    to Annex X.
            2:      AnnexX_FORCED: Operation according to Annex X is forced. If one or both of the FTUs does not
                    support  Annex  X,  the  handshake  procedure  shall  terminate  with  'no  mode  selected'  (see
                    Figures 12-4 and 12-5). In this case the "Annex X operation" bit in the FTU-O CL message NPar(2)
                    (see Table X.5) shall be set to ZERO if the FTU-O does not support operation according to Annex X
                    and shall be set to ONE if the FTU-O supports operation according to Annex X.

            The  control  parameter  Annex_X_mode  shall  be  set  to  the  same  value  as  the  DPU-MIB  configuration
            parameter ANNEX_X_MODE.

            X.6.7.2    DTA allowed (DTA_allowed)

            The  control  parameter  DTA_allowed  determines  whether  DTA  operation  is  allowed  with  valid  values  1
            (allowed) and 0 (not allowed). If DTA operation is allowed and Annex X operation mode is selected, the
            FTU-O shall enable DTA and indicate this to the FTU-R during initialization (see clause X.7.2.1).
            The  control  parameter  DTA_allowed  shall  be  set  to  the  same  value  as  the  DPU-MIB  configuration
            parameter DTA_ALLOWED.