Page 866 - 5G Basics - Core Network Aspects
P. 866

2                                                 Transport aspects


            The Q shall be represented as an eight-bit unsigned integer.

            A special value 255 indicates that the parameter is undetermined.
            All other values are reserved by ITU-T.

            The Q value shall be reported by the FTU-O as DTU-Q in the DPU-MIB.
            The downstream and upstream values shall be reported in the DPU-MIB.

            During the L3 link state (see Figure 12-1), the values of the last update are available in the DPU-MIB, until
            the FTU-O transitions to the O-INIT/HS state, at which time the values may become "undetermined".

            11.4.1.1.19 Bit Allocation on data subcarriers (bi)
            The status parameter bi is the bit allocation values as defined in clause 10.2.1.4 on data symbols in the
            normal operation interval (NOI) in L0, and on data subcarriers on the RMC symbols during the L2.1N, L2.1B
            and L2.2 link states.
            The bi shall be updated during showtime (L0, L2.1N, L2.1B and L2.2 link states).
            The valid values for bi are all integers from 0 to 14.

            The bi shall be represented as an eight-bit unsigned integer.
            A special value 255 indicates that the parameter is undetermined. All other values are reserved by ITU-T.

            The bi value shall be reported by the FTU-O as BITSps in the DPU-MIB.
            The downstream and upstream values shall be reported in the DPU-MIB.

            During the L3 link state (see Figure 12-1), the values are "undetermined".
            11.4.1.1.20 Bit Allocation on RMC subcarriers (bRMCi)

            The status parameter bRMCi is the bit allocation values as defined in clause 10.2.1.4 on RMC subcarriers in
            RMC symbols.

            The bRMCi shall be updated during showtime (L0, L2.1N, L2.1B and L2.2 link states).
            The valid values for bi are 0 and all integers from 2 to 6.

            The bRMCi shall be represented as an eight-bit unsigned integer.
            A special value 255 indicates that the parameter is undetermined. All other values are reserved by ITU-T.

            The bRMCi value shall be reported by the FTU-O as BITS-RMCps in the DPU-MIB.
            The downstream and upstream values shall be reported in the DPU-MIB.
            During the L3 link state (see Figure 12-1), the values are "undetermined".

            11.4.1.2   Test parameters

            11.4.1.2.1  Hlog-psg
            Hlog provides an estimate of the insertion loss of the wireline channel.

            The  definition  of the  insertion  loss  is −20*LOG10(|U2(f)/U1(f)|)  dB.  U1(f)  is the  voltage  as  a  function of
            frequency  measured  across  the  load  impedance  RL  in  the  absence  of  the  wireline  channel  as  shown  in
            Figure 11-7 for the downstream direction. U2(f) is the voltage as a function of frequency measured across
            the load impedance RL in the presence of the wireline channel as shown in Figure 11-8 for the downstream
            direction.










            856
   861   862   863   864   865   866   867   868   869   870   871