Page 861 - 5G Basics - Core Network Aspects
P. 861

Transport aspects                                              2


            11.4.1.1.7  Actual INP against SHINE (INP_act_shine)

            The  status  parameter  INP_act_shine  is  defined  as the  actual  INP  against  SHINE  under  following  specific
            conditions:
            •       Assuming impulse noise protection against REIN equal to INP_min_rein
            •       Assuming EFTR ≥ ETR.
            It shall be calculated by the transmitter during initialization and showtime during the L0, L2.1N, L2.1B and
            L2.2 link states and updated upon OLR.
            The status parameter INP_act_shine shall be represented as a 16-bit unsigned integer expressing the value
            in symbol periods in steps of 1 symbol period.
            The valid range is from 0 to 2 046.

            A special value 2 047 indicates a value of 2 047 or higher.
            A special value 2 –1 indicates that the parameter is undetermined.
                           16
            All other values are reserved by ITU-T.
            The status parameter INP_act_shine shall be mapped on the reporting parameter ACTINP. The downstream
            and upstream values shall be reported in the DPU-MIB.
            During the L3 link state (see Figure 12-1), the values of the last update are available in the DPU-MIB, until
            the FTU-O transitions to the O-INIT/HS state, at which time the values may become "undetermined".

            11.4.1.1.8  Actual INP against REIN (INP_act_rein)
            The status parameter INP_act_rein is defined as the actual INP against REIN under the following specific
            conditions:
            •       Assuming impulse noise protection against SHINE equal to INP_min_shine,
            •       Assuming EFTR ≥ ETR.

            It shall be calculated by the transmitter during initialization and showtime during the L0, L2.1N, L2.1B and
            L2.2 link states and updated upon OLR.

            The status parameter INP_act_rein shall be represented as an eight-bit unsigned integer expressing the
            value in symbol periods in steps of one symbol period.

            The valid range is from 0 to 62.
            A special value 63 indicates a value of 63 or higher.
                           8
            A special value 2 -1 indicates that the parameter is undetermined.
            All other values are reserved by ITU-T.

            The  test  parameter  INP_act_rein  shall  be  mapped  on  the  reporting  parameter  ACTINP_REIN.  The
            downstream and upstream values shall be reported in the DPU-MIB.

            During the L3 link state (see Figure 12-1), the values of the last update are available in the DPU-MIB, until
            the FTU-O transitions to the O-INIT/HS state, at which time the values may become "undetermined".

            11.4.1.1.9  Error-free bits counter
            This is a near-end counter counting the number of error-free bits passed over the  reference point at the
                                16
            receiver, divided by 2 . Error-free bits are DTU payload bits originating from DTUs of the normal DTU type
            (see clause 8.2.1.3) that cross the  reference point at the receiver.









                                                                                                         851
   856   857   858   859   860   861   862   863   864   865   866