Page 747 - 5G Basics - Core Network Aspects
P. 747

Transport aspects                                              2




                                  Table 9-8 – Upstream RMC command (sent by FTU-R only)

                   Field name               Format                             Description
             Current active bit-loading  One byte: [bbbb aaaa]   Indication for the active bit-loading table to be used in the
             table identifier                               current logical frame, expressed as a value of FCCC
                                                            (see clause 13.3.1.1.3).
                                                            aaaa = Identifier for the active bit-loading table to be used
                                                            over the NOI.
                                                            bbbb = Identifier for the active bit-loading table to be
                                                            used over the DOI (Note 1).
             Settings associated with   One byte: [aa 000000]   Contains settings associated with the supported options
             supported options                              (Note 2)
                                                            aa = indicator bits for RPF in the following order [dgl ohp]
                                                            (see clause 11.3.3.2).
                                                            An indicator bit shall be set to 0 if the corresponding
                                                            primitive occurs and set to 1 otherwise (active low).
                                                            All other bits are reserved by ITU-T and shall be set to 0.

             NOTE 1 – If only the NOI is used (i.e., if TTR ds ≥ TBUDGET ds) for a given logical frame, the identifier corresponding to the DOI shall
             be set to 0000 by the transmitter and ignored by the receiver.
             NOTE 2 – This byte shall be present if and only if support of at least one of the options for which settings are conveyed via this
             byte are indicated by both FTUs during initialization (first byte of the field "supported options", see clauses 12.3.4.2.1 and
             12.3.4.2.2).


                                  Table 9-9 – Format for upstream logical frame parameters

               Field name           Format                                 Description

             TTRus           One byte: [00 aaaaaa]   aaaaaa = TTRus, the number of symbol positions in the NOI of the
                                                    logical frame, coded as an unsigned integer.
                                                    Valid range is from one to 25 inclusive.
             TAus            One byte: [000 aaaaa]   aaaaa = TAus, the number of quiet symbols at the beginning of the
                                                    DOI of the logical frame, coded as an unsigned integer.
                                                    Valid range is from zero to 24 inclusive.

             TBUDGETus       One byte: [00 aaaaaa]   aaaaaa = the value of the parameter TBUDGETus (see clause 10.7),
                                                    coded as an unsigned integer.
                                                    Valid range is from one to 25 inclusive.


























                                                                                                         737
   742   743   744   745   746   747   748   749   750   751   752