Committed to connecting the world

  •  
wtisd

ITU-T Recommendations

Search by number:
Others:
Skip Navigation Links
Content search
Advanced search
Provisional name
Equivalent number
Formal description
Study Groups tree viewExpand Study Groups tree view

ITU-T K.20 (04/2008)

عربي | 中文 | English | Español | Français | Русский
Resistibility of telecommunication equipment installed in a telecommunications centre to overvoltages and overcurrents
Recommendation ITU-T K.20 specifies resistibility requirements and test procedures for telecommunication equipment that is installed in a telecommunication centre.Overvoltages or overcurrents covered by this Recommendation include surges due to lightning on or near the line plant, short-term induction from adjacent a.c. power lines or railway systems, earth potential rise due to power faults, direct contacts between telecommunication lines and power lines and electrostatic discharges. The sources for overvoltages in internal lines, between equipment/racks, are mainly inductive coupling caused by lightning currents being conducted in nearby lightning strokes or lightning currents being conducted in nearby conductors.Major changes compared with the 2003 version of this Recommendation include:
• removing the power induction test requirement for antenna ports where the installation is within the scope of Recommendation ITU-T K.71;
• addition of information on equipment included and excluded in scope;
• clearer definition of when the internal and external port classification applies to antenna ports.
Citation: https://handle.itu.int/11.1002/1000/9400
Series title: K series: Protection against interference
Approval date: 2008-04-13
Approval process:AAP
Status: Superseded
Maintenance responsibility: ITU-T Study Group 5
Further details: Patent statement(s)
Development history
[8 related work items in progress]