Page 905 - Cloud computing: From paradigm to operation
P. 905

Intercloud and interoperability                                     5




                                   Table II.14 – Test case: physical machine status inquiring

                                     Physical machine configuration inquiring test description
             Test sequence   Step      Type                          Description                      Result
                            1      Stimulus      The CSC queries the CPU’s cores number of the physical
                                                 machine from the CSP.

                            2      Check         The CSC receives the information of a particular physical
                                                 machine's CPU cores number that is consistent with the CPU
                                                 cores number of the physical machine.
                            3      Stimulus      The CSC queries memory size of the physical machine from
                                                 the CSP.
                            4      Check         The CSC receives the information of a particular physical
                                                 machine's memory size that is consistent with the memory
                                                 size of the physical machine.
                            5      Stimulus      The CSC queries the disk size of the physical machine from
                                                 the CSP.
                            6      Check         The CSC receives the information of a particular physical
                                                 machine's disk size that is consistent with the disk size of the
                                                 physical machine.
                            7      Stimulus      The CSC queries The NIC number of the physical machine
                                                 from the CSP.
                            8      Check         The CSC receives the information of a particular physical
                                                 machine's NIC number that is consistent with the NIC
                                                 number of the physical machine.
             Test verdict   It is deemed as successfully terminated if all the checks are successful, otherwise it is
                            deemed as failed.

            II.2    Test cases for storage service interoperability testing between the CSC and CSP

            II.2.1   Test case: storage migration
            Table II.15 shows the test case for storage migration.


                                          Table II.15 – Test case: storage migration

                                              Storage migration test description
             Test purpose          To verify that the CSC migrates data of the VM to different storage media without any
                                   loss.
             Reference             [ITU-T Y.3513] clause 7.2.1
             Test sequence   Step      Type                          Description                      Result
                            1      Stimulus      The CSC migrates the VM's data from local storage to shared
                                                 storage.
                            2      Check         The VM uses the shared storage after migration is done
                                                 without affecting the service running on the VM.
                            3      Stimulus      The CSC migrates the VM's data from shared storage to local
                                                 storage.
                            4      Check         The VM uses the local storage after migration is done
                                                 without affect the service running on the VM.

             Test verdict   It is deemed as successfully terminated if all the checks are successful, otherwise it is