Page 981 - 5G Basics - Core Network Aspects
P. 981

Transport aspects                                              2






































                                 Figure 13-6 – TIGA procedure with non-segmented messages


            In response to a TIGA-ACK or TIGARESP message, the VCE shall instruct (over the γ_MGMT interface), the
            FTU-O to either:

            –       send an SRA-R RMC command (see Table 9-4 and Table 9-15), to indicate the symbol position on
                    which  both  FTU-O  and  FTU-R  implement  the  new  parameters  values  (see  clause 13.2.2.1.2  for
                    details and timing). The value of SCCC that the FTU-O shall send in the SRA-R command, shall be
                    instructed by the VCE over the γ_MGMT interface with one of the following options:
                    •   the value of SCCC as received in the TIGARESP message, to indicate that the FTU-O did receive
                        the TIGARESP message, and that the precoder, the relative gain compensation factors ri, the
                        baseline bit loading table and all other parameter values shall be established corresponding to
                        the values requested in the TIGARESP message, or
                    •   the  special  value  SCCC=1111,  to  indicate  that  the  FTU-O  did  not  receive  the  TIGARESP
                        message, but that nevertheless the precoder, the relative gain compensation factors ri, and
                        the baseline bit loading table shall be established corresponding to the values indicated in the
                        TIGA command, while all other parameter values which are part of a TIGARESP message shall
                        stay unchanged, or
                    •   the  special  value  SCCC=1110,  to  indicate  that  the  FTU-O  did  not  receive  the  TIGARESP
                        message,  but  that  nevertheless  the  precoder  and  the  relative  gain  compensation  factors  ri
                        shall be established corresponding to the values indicated in the TIGA command, while the
                        baseline bit loading tables and all other parameter values that are part of a TIGARESP message
                        shall stay unchanged, or
                    •   the special value SCCC=1101, to indicate that the FTU-O did not receive a TIGA-ACK, but that
                        nevertheless the precoder and the relative gain compensation factors ri shall be established
                        corresponding to the values indicated in the TIGA command while the baseline bit loading
                        table  and  all  other  parameter  values  that  are  part  of  a  TIGARESP  message  shall  stay
                        unchanged, or
                    •   resend the OLR request type 3 (TIGA) command in case the FTU-O did not receive the TIGA
                        ACK.


                                                                                                         971
   976   977   978   979   980   981   982   983   984   985   986