2                                                 Transport aspects


                                               Table 12-52 – O-PMD message

                Field                  Field name                                  Format

                 6      Tone ordering table                      3 × ceiling(NSCus/2) bytes coded as follows:
                                                                 •  Bits 0-11: t2n–1
                                                                 •  Bits 12-23: t2n
                 7      Initialization status                    One byte
                 8      Upstream gi table                        3 × ceiling(NSCus/2) bytes

                 9      Upstream FRA sub-bands                   Sub-band descriptor
            Field 1 "Message descriptor" is a unique one-byte code (0A16) that identifies the message. See Table 12-7
            for a complete list of codes.
            Field  2  "Bit-loading  table  for  data  symbol  during  NOI"  contains  the  bi  values  for  every  subcarrier  in
            MEDLEYus. The bi shall indicate the number of bits to be mapped by the FTU-R to the subcarrier i.

            The bi shall only be defined for subcarriers from the MEDLEYus set (as indicated in O-PRM message), and
            shall be sent in ascending order of subcarrier index i.

            Each bi value shall be represented as an unsigned 4-bit integer with valid range from zero to 12. The four
            least significant bits of the first byte of this field represent the bit loading of the first subcarrier from the
            MEDLEYus set. The four most significant bits of the first byte of this field represent the bit loading of the
            second subcarrier from the MEDLEYus set. The four least significant bits of the second byte of this field
            represent the bit loading of the third subcarrier from the MEDLEYus set, etc.

            Field  3  "Number  of  RMC  US  subcarriers  (NSCRus)"  indicates  the  number  of  subcarriers  assigned  for
            upstream RMC symbol represented as an unsigned integer. The valid range is from 1 to 512 (020016).

            Field 4 "Upstream RMC tone set (RTSus)" indicates the indices of the subcarriers used to encode the RMC in
            the upstream direction. Each subcarrier index shall be represented as a 12-bit value. Pairs of subcarrier
            indices shall be mapped to a field of three bytes. For example,  if the value of the nth field is 40020016,
            rsc2n−1 = 20016 = 512 and rsc2n = 40016 = 1 024. If the number of subcarriers in the RTSus set is odd, the
            last 12 bits of the field shall be set to ZERO (and ignored by the receiver). The first encoded value shall
            correspond  to  the  lowest  subcarrier  used  to  encode  the  RMC.  The  remaining  indices  shall  be  sent  in
            increasing frequency order. The subcarriers for RTSus shall be selected from the MEDLEYus set.
            Field 5 "Bit-loading table for RMC US subcarriers" contains the bi values for every subcarrier in upstream
            RMC subcarrier set presented in field 3. The bi shall indicate the number of bits to be mapped by the FTU-R
            to the subcarrier i. The bi values shall be sent in ascending order of subcarrier index i. Each bi value shall be
            represented as an unsigned 4-bit integer with valid values of 0 and from 2 to 6.

            Field  6  "Tone  ordering  table"  contains  the  tone  ordering  table  t  for  the  upstream  direction.  The  tone
            ordering table contains the order in which the subcarriers shall be assigned bits in the upstream direction.
            The table shall include all subcarriers of the MEDLEYus set and only these subcarriers. Each subcarrier index
            shall be represented as a 12-bit value. Pairs of subcarrier indices shall be mapped to a field of three bytes.
            For example, if the value of the nth field is 40020016, t2n−1 = 20016 = 512 and t2n = 40016 = 1 024. If the
            number of subcarriers in the MEDLEYus set is odd, the last 12 bits of the field shall be set to ZERO (and
            ignored by the receiver). The value of the first index sent shall be equal to the index of the first entry in the
            tone ordering table (t1, see clause 10.2.1.2). The remaining indices shall be sent in increasing order of the
            tone ordering table t entries (t2, t3, ... tNSCus).

            Field 7 "Initialization status":
            If, within the constraints of the channel initialization policies defined in clause 12.3.7, the receiver is unable
            to select a set of configuration parameters, the receiver shall reply with an "Initialization success/failure
            code" indicating the initialization failure cause.