                                            Table 7-3 – supra-2.488G CBR clients

                                                      Nominal bit rate                Bit-rate tolerance
                    [CPRI] client signal
                                                          (kbit/s)                         (ppm)
             Option 4                       3 072 000                           0.002
             Option 5                       4 915 200                           0.002
             Option 6                       6 144 000                           0.002

             Option 7                       9 830 400                           0.002
             Option 8                       10 137 600                          0.002
             Option 9                       12 165 120                          0.002
             Option 10                      24 330 240                          0.002

            Table 7-4 shows the replacement signal for CPRI clients.


                                       Table 7-4 – Replacement signal for CPRI clients

                    [CPRI] client signal             Replacement signal             Bit-rate tolerance (ppm)
             Option 1                       Link fault                          100
             Option 2                       Link fault                          100
             Option 3                       Link fault                          100
             Option 4                       Link fault                          100
             Option 5                       Link fault                          100
             Option 6                       Link fault                          100
             Option 7                       Link fault                          100
             Option 8                       TBD                                 100
             Option 9                       TBD                                 100
             Option 10                      TBD                                 100

            Table 7-5 shows the number of tributary slots required for ODUj into HO OPUk and OPUCn.

                       Table 7-5 – Number of tributary slots required for ODUj into HO OPUk and OPUCn


                                       # 2.5G tributary
                                                               # 1.25G tributary slots     # 5G tributary slots
                                           slots
                     LO ODU           OPU2     OPU3     OPU1     OPU2     OPU3     OPU4          OPUCn
                     – [CPRI]

             ODUflex(CBR)
             – ODUflex(option 4)        –        –        –        3       3         3             1
             – ODUflex(option 5)        –        –        –        4       4         4             1
             – ODUflex(option 6)        –        –        –        5       5         5             2
             – ODUflex(option 7)        –        –        –        8       8         8             2
             – ODUflex(option 8)        –        –        –        –       9         8             2
             – ODUflex(option 9)        –        –        –        –       10       10             3
             – ODUflex(option 10)       –        –        –        –       20       19             5
            Table 7-6 shows Cm and Cn (n = 8) for ODUj into ODTU2.M.