Page 281 - Shaping smarter and more sustainable cities - Striving for sustainable development goals
P. 281

AC/DC


                                            Grid

                                      Solar panel
                                                          Battery
                                                  HPS2000E


                                                                       Load


                                          DC     AC



                         Figure 44 – Example of radio site powered by AC main and solar energy
            The equipment used to build the ICT infrastructure need to be high efficiency equipment to reduce
            their impact and energy consumption respect to their use.

            Definition of energy efficiency metrics for ICT is available in ITU‐T Recommendation L.1310 "Energy
            efficiency  metrics  and  measurement  methods  for  telecommunication  equipment      25  ".  This
            Recommendation  also  specifies  the  principles  and  concepts  of  energy  efficiency  metrics  and
            measurement methods for small networking equipment used in the home and small enterprise
            locations. The Recommendation defines that when transmission time and frequency bandwidth are
            fixed, a telecommunication system that can transport more data (in bits) with less energy (in Joules)
            is considered to be more energy efficient.
            The efficiency of infrastructure equipment is considered in ITU‐T Recommendation L.1320: "Energy
            efficiency metrics and measurement for power and cooling equipment for telecommunications and
            data  centers  26  ".  The  methodologies  defined  in  this  Recommendation  are  applied  at  single
            equipment  level.  The  efficiency  of  power  conversion  and  cooling  in  the  data  center  or
            telecommunication  facility  is  only  partially  attributed  to  the  equipment.  The  architecture  and
            organization of the space and equipment to deliver the power or cooling to the systems is an equal,
            if  not  a  more  significant  factor  to  energy  efficiency.  Another  general  factor  will  be  the

            ____________________
            25  Recommendation  ITU‐T  L.1310  contains  the  definition  of  energy  efficiency  metrics  test  procedures,
               methodologies and measurement profiles required to assess the energy efficiency of telecommunication
               equipment.  Energy  efficiency  metrics  and  measurement  methods  are  defined  for  telecommunication
               network  equipment  and  small  networking  equipment.  These  metrics  allow  for  the  comparison  of
               equipment within the same class, e.g., equipment using the same technologies.
            26  Recommendation ITU‐T L.1320 contains the general definition of metrics, test procedures, methodologies
               and measurement profiles required to assess the energy efficiency of power and cooling equipment for
               telecommunications and data centers. More detailed measurement procedures and specifications can be
               developed in future related ITU‐T Recommendations. Metrics and measurement methods are defined for
               power equipment, alternating current (AC) power feeding equipment (such as AC uninterruptible power
               supply (UPS), direct current (DC/AC) inverters), DC power feeding equipment (such as AC/DC rectifiers,
               DC/DC converters), solar equipment, wind turbine equipment and fuel cell equipment. In addition, metrics
               and  measurement  methods  are  defined  for  cooling  equipment  such  as  air  conditioning  equipment,
               outdoor air cooling equipment and heat exchanging cooling equipment.

            ITU‐T's Technical Reports and Specifications                                                 271