AAP Recommendation

K.147: Protection of networked information technology equipment

Study Group
5

Study Period
2017-2020

Consent Date
2021-05-20

Approval Date
2022-01-13

Provisional Name


Input used for Consent
SG5-TD1864

Status
AC

IPR
Site

Ethernet, using twisted-pair cabling, is a ubiquitous communications link, which also can act as a powering feed. Usually, Ethernet is implemented as a star network and terminal ports can be independently tested for resistibility. Where equipment has multiple independent Ethernet ports, such as central hubs, switches, or repeaters, then testing is required for inter-port resistibility. Resistibility testing needs to test for lightning transients coupled into a network by magnetic induction, earth potential rise, resistive coupling and transient coupling by a voltage-limiting operation of surge protective functions or flashover. The voltage limiting operation may convert common-mode surges into differential-mode surges in the signal path. It is also possible for alternating current (AC) mains power faults to couple into the network. Recommendation ITU-T K.147 covers the different Ethernet implementations, their configurations, how surges are coupled into the system and what surge mitigation measures are used. Following this overview, the rational for the different surge and power fault test circuit approaches and when they are specified is given.

Please see revised title.

AAP Current Status
Step # Action
Start / End
Status Announcement Related documents Comments / Resolution logs