Page 220 - Cloud computing: From paradigm to operation
P. 220

1                                    Framework and requirements for cloud computing




                              Table I.5 – Relationship with related specifications from other SDOs

              NO.     Requirements in this          Relationship with related specifications from other SDOs
                       Recommendation
               52    Support fault location   –  [b-ETSI EVE007] provide fault location support as 'hardware with fast failure
                                              detection' in clause 5.11.
                                           –  [b-OCP 1S] provide fault location as 'these errors must include the date,
                                              time and location information so that failing components can be easily
                                              identified' in clause 9.6.10.
                                           –  [b-OCP 2S] provide fault location as 'A power failure detection circuit needs
                                              to be implemented to initiate 3x actions related to data transferring' in
                                              clause 5.3.3.
                                           –  [b-OCP 2S] provide fault location as 'All POST errors, which are detected by
                                              BIOS during POST, should be logged into Event Log' in clause 9.11.1.
                                           –  [b-OCP Yose] provide fault location as 'Fan failure errors should be logged if
                                              the fan speed reading is outside expected ranges between the lower and
                                              upper critical thresholds. The Error log should also identify which fan fails' in
                                              clause 6.15.1.7.
               53    Hot-plug support      –  [b-ETSI EVE007] provide hot-plug support as 'Supporting hot-plug for
                                              vulnerable components, including hard drive and optical modules' in
                                              clause 5.11.
                                           –  [b-OCP OCSPS] provide hot-plug support as 'The power supply shall be hot
                                              pluggable' in clause 1.
                                           –  [b-OCP OCSB] provide hot-plug support as 'The blade contains a NIC
                                              mezzanine card to provide small form-factor pluggable (SFP+) and Quad SFP
                                              (QSFP+) cable connectivity' in clause 7.2.
                                           –  [b-OCP 2S] provide hot-plug support as 'the x32 PCIe in riser slot shall
                                              support Standard PCIe signal hot swap' in clause 5.5.2.
                                           –  [b-OCP TP] provide hot-plug support as 'PCIe Hot Plug' in clause 5.5.1.