            5       Reference models and system requirements

            5.1     System reference models

            This Recommendation covers the interface specification between an FTU-O and FTU-R, as applied at the U
            reference point. The FTU-O is located inside the distribution point unit (DPU) at the network side of the
            wire-pair (U-O reference point). The FTU-R is located inside the network termination (NT) at the customer
            premises  side  of  the  wire-pair  (U-R  reference  point).  Implementations  complying  with  this
            Recommendation are typically deployed in a fibre to the-distribution point (FTTdp) scenario.
            The functional reference model of FTTdp deployment is illustrated in Figure 5-1.
            The  upstream  traffic  from  all  DPUs  is  aggregated  by  the  optical  distribution  network  (ODN)  and  higher
            order  node  (HON)  up  to  the  V  reference  point.  The  downstream  traffic  at  the  V  reference  point  is
            distributed towards multiple DPUs by HON and ODN. The aggregation and distribution functions of ODN
            and HON are out of the scope of this Recommendation. Different aggregation examples are united under
            HON, ODN and DPU, as shown in Figure 5-1.

            Each DPU is located at a distribution point and contains one or more FTU-Os, with each FTU-O connected to
            a NT. The NT contains an FTU-R, which is a peer of the FTU-O connected to the corresponding DPU.

            The management of a DPU is performed by the network management system (NMS), passing management
            information to each DPU's management entity (ME) over the Q reference point. The NMS may also monitor
            each FTU-R via the related NT's ME via the G reference point. The connection between the ME functions at
            the DPU and at the NT is established over management channels provided by the FTU-Os and FTU-Rs via