Page 1112 - 5G Basics - Core Network Aspects
P. 1112

2                                                 Transport aspects


                                            Table 7-2  ODU types and bit rates

                      ODU type                    ODU nominal bit rate              ODU bit-rate tolerance

             ODU0                         1 244 160 kbit/s
             ODU1                         239/238 × 2 488 320 kbit/s
             ODU2                         239/237 × 9 953 280 kbit/s
                                                                                         20 ppm
             ODU3                         239/236 × 39 813 120 kbit/s
             ODU4                         239/227 × 99 532 800 kbit/s
             ODUCn                        n × 239/226 × 99 532 800 kbit/s
             ODU2e                        239/237 × 10 312 500 kbit/s                    100 ppm
             ODUflex for CBR              239/238 × client signal bit rate
                                                                                    100 ppm (Notes 2, 3)
             client signals
             ODUflex for GFP-F mapped     Configured bit rate (see Table 7-8)            100 ppm
             client signals
             ODUflex for IMP mapped client   s × 239/238 × 5 156 250 kbit/s              100 ppm
             signals                      s = 2, 8, n × 5 with n ≥ 1 (Note 4)
             ODUflex for FlexE-aware client   103 125 000 × 240/238 × n/20 kbit/s        ± 100 ppm
             signals                      (n = n1 + n2 + .. + np)

             NOTE 1 – The nominal ODU rates are approximately: 2 498 775.126 kbit/s (ODU1), 10 037 273.924 kbit/s (ODU2), 40 319 218.983
             kbit/s (ODU3), 104 794 445.815 kbit/s (ODU4), 10 399 525.316 kbit/s (ODU2e), n × 105 258 138.053 kbit/s (ODUCn).
             NOTE 2 – The bit-rate tolerance for ODUflex(CBR) signals is specified as 100 ppm. This value may be larger than the tolerance
             for the client signal itself (e.g., 20 ppm). For such case, the tolerance is determined by the ODUflex(CBR) maintenance signals,
             which have a tolerance of 100 ppm.
             NOTE 3 – For ODUflex(CBR) signals with nominal bit rates close to the maximum ODTUk.ts payload bit rate and client rate
             tolerances less than 100 ppm (e.g., 10 ppm), the ODUflex(CBR) maintenance signal bit rates may exceed the ODTUk.ts payload
             bit rate. For such cases either an additional tributary slot may be used (i.e., ODTUk.(ts+1)), or the nominal bit rate of the
             ODUflex(CBR) signal may be artificially reduced to a value of 100 ppm below the maximum ODUflex(CBR) signal bit rate.
             NOTE 4 – Refer to clause 12.2.6 for considerations on the values of "s".


                                            Table 7-3  OPU types and bit rates

                       OPU type               OPU payload nominal bit rate     OPU payload bit-rate tolerance

             OPU0                         238/239 × 1 244 160 kbit/s
             OPU1                         2 488 320 kbit/s
             OPU2                         238/237 × 9 953 280 kbit/s
                                                                                         20 ppm
             OPU3                         238/236 × 39 813 120 kbit/s
             OPU4                         238/227 × 99 532 800 kbit/s
             OPUCn                        n × 238/226 × 99 532 800 kbit/s
             OPU2e                        238/237 × 10 312 500 kbit/s                   100 ppm
             OPUflex for CBR              client signal bit rate             client signal bit-rate tolerance,
             client signals                                                  with a maximum of 100 ppm
             OPUflex for GFP-F mapped     238/239 × ODUflex signal rate                 100 ppm
             client signals
             OPUflex for IMP mapped client   s × 5  156 250 kbit/s                      100 ppm
             signals                      s = 2, 8, n × 5 with n ≥ 1 (Note 2)

             OPUflex for FlexE-aware client   103 125 000 × 240/239 × n/20 kbit/s       ± 100 ppm
             signals                      (n = n1 + n2 + .. + np)




            1102
   1107   1108   1109   1110   1111   1112   1113   1114   1115   1116   1117