Page 917 - Cloud computing: From paradigm to operation
P. 917

Intercloud and interoperability                                     5




                         Table III.1 – Alignment analysis with functional requirements in [ITU-T Y.3513]

                            Functional requirements in [ITU-T Y.3513]       Test objects in this Recommendation
             26    7.2 Storage   –  It is recommended that the IaaS CSP    –  8.6 Interoperability testing of
                   service          provides storage functions, such as block   storage life cycle management
                   functional       level storage, file level storage and object-  between the CSC and CSP
                   requirements     based storage, with specific SLAs and
                                    charging model to the CSC. The storage
                                    functions can be provided to the CSC directly
                                    or used by the virtual machine as attached
                                    storage.

             27                  –  It is recommended that the IaaS CSP    –  8.6 Interoperability testing of
                                    provides the CSC with operations handling   storage life cycle management
                                    mechanisms related to storage, such as    between the CSC and CSP
                                    create, attach, detach, query and delete a
                                    volume of storage at either block level or
                                    file-system level, write, read and delete data
                                    for a given storage.

             28                  –  It is recommended that the IaaS CSP    –  8.7 Interoperability testing of
                                    provides storage utilisation information in   storage utilization status inquiring
                                    response to queries from the CSC.         between the CSC and CSP
             29    7.2.1 Storage   –  It is recommended that the IaaS CSP   –  8.1 Interoperability testing of
                   migration        provides storage migration functions. Based   storage migration between the CSC
                                    on migration policies, data can be migrated   and CSP
                                    between different logical unit numbers
                                    (LUNs), different storage devices, local
                                    storage to shared storage and vice versa.
             30    7.2.2 Storage   –  It is recommended that the IaaS CSP   –  8.2 Interoperability testing of
                   snapshot         provides storage with snapshot functions.   storage snapshot between the CSC
                                    Snapshot can be realized at either block or   and CSP
                                    file-system levels. The data can be restored
                                    using the snapshot.
             31    7.2.3 Storage   –  It is recommended that the IaaS CSP   –  8.3 Interoperability testing of
                   backup           provides storage with backup functions.   storage backup between the CSC
                                    Backup can be realized at block level, file   and CSP
                                    level or object-based storage.
             32    7.2.4 I/O     –  It is recommended that the IaaS CSP    –  8.5 Interoperability testing of I/O
                   performance      provides input/output (I/O) limitation for   performance between the CSC and
                                    each VM.                                  CSP
             33    7.2.5 Storage   –  It is recommended that the IaaS CSP   –  8.4 Interoperability testing of
                   resource         provides storage resource (e.g., storage   storage resource reservation
                   reservation      space and LUN) reservation functions.     between the CSC and CSP
             34    7.3 Network   –  It is recommended that the IaaS CSP    –  9.7 Interoperability testing of load
                   service          provides network functions, such as IP    balance between the CSC and CSP
                   functional       address, VLAN, virtual switch, load balance,   –  9.8 Interoperability testing of
                   requirements     firewall, with specific SLAs or charging   firewall between the CSC and CSP
                                    model. Network functions are applied to
                                    access and interconnect processing and
                                    storage resources.

             35                  –  It is recommended that the IaaS CSP    –  9.10 Interoperability testing of
                                    provides network information in response to   network information inquiring
                                    queries from the CSC.                     between the CSC and CSP




                                                                                                         909
   912   913   914   915   916   917   918   919   920   921   922