Page 1151 - 5G Basics - Core Network Aspects
P. 1151
Transport aspects 2
Table 15-4 ODU PM BEI interpretation
ODU PM BEI
BIP violations
bits 1 2 3 4
0 0 0 0 0
0 0 0 1 1
0 0 1 0 2
0 0 1 1 3
0 1 0 0 4
0 1 0 1 5
0 1 1 0 6
0 1 1 1 7
1 0 0 0 8
1 0 0 1 0
to
1 1 1 1
15.8.2.1.5 ODU PM status (STAT)
For path monitoring, three bits are defined as status bits (STAT). They indicate the presence of a
maintenance signal (see Table 15-3).
A P-CMEP sets these bits to "001".
The ODUk and ODUCn contain one instance of ODU PM STAT overhead.
Table 15-5 ODU PM status interpretation
PM byte 3
Status
bits 6 7 8
0 0 0 Reserved for future international standardization
0 0 1 Normal path signal
0 1 0 Reserved for future international standardization
0 1 1 Reserved for future international standardization
1 0 0 Reserved for future international standardization
1 0 1 Maintenance signal: ODU-LCK
ODUk: Maintenance signal: ODU-OCI
1 1 0
ODUCn: Reserved for future international standardization
1 1 1 Maintenance signal: ODU-AIS
15.8.2.1.6 ODU PM delay measurement (DMp)
For ODU path monitoring, a one-bit path delay measurement (DMp) signal is defined to convey the start of
the delay measurement test.
The ODUk and ODUCn contain one instance of ODU PM DMp overhead.
The DMp signal consists of a constant value (0 or 1) that is inverted at the beginning of a two-way delay
measurement test. The transition from 01 in the sequence …0000011111…, or the transition from 10
in the sequence …1111100000… represents the path delay measurement start point. The new value of the
DMp signal is maintained until the start of the next delay measurement test.
1141