Page 330 - Shaping smarter and more sustainable cities - Striving for sustainable development goals
P. 330

3.7.1   Home energy management

            Visualization service of consumed energy

            The system is required to measure the consumed electric energy of each distributer, breakers the
            generated energy by solar cells, and allow to calculate the fee of energy and to inform the cable
            customer of the result. The current sensor is required to transmit measured data (consumed or
            generated electric power) to the radio terminal device by ZigBee or wireless fidelity (Wi‐Fi) radio
            chip. The residential gateway (RGW) is required to store the data temporarily (e.g., for one day) and
            to upload the data to the collection server of sensor information.
            The system is also required to present the cable customer with a regional power saving period, a
            power saving announcement, and information on power balance from a municipal office or power
            company. In other words, the system should not only display consumed/generated power. The
            system can provide, optionally, recommend services for power and cost saving, in line with the
            customer's power consumption pattern.
            Furthermore, the system can optionally provide any additional support including regional ranking
            information of power saving or additional incentive services. The system is required to be operated
            on RGW at home and on a smart phone or tablet terminal, and in an outdoor environment through
            the cable portal function. The system is required to send the information by e‐mail to the assigned
            address.


































                               Figure 78 – RGW and related entities for home ICT services

            Source: Technical Report of the Focus Group on Smart Cable Television.
            Solar power cell maintenance service
            This is an information service to the cable customer on the maintenance of the solar power cell. The
            system is required to report to the cable customer the necessity of surface cleaning, the existence
            of  malfunction  through  the  monitoring  of  past  power  generation  record  and  comparison  with
            regional standard generation value.