Page 1066 - 5G Basics - Core Network Aspects
P. 1066

2                                                 Transport aspects


                              Table I.1 – Detailed loop and noise characteristics of the final drop

               Loop           Patch section               Proximal section              Radial section

                       Metres    Type     Xtalk     Metres     Type      Xtalk     Metres     Type    Xtalk
             D1-US       0.6    A26j        2         60     A26u      10            93      A24u       0
             D2-US       0.6    A26j        2         –      –         –             90      A24u       0

             D3-UK       0.6    B05         1     Null                               35      B05a       1
             D4-UK       0.3    B05         1         3      B05u      2             70      B05a       1
             D5          0.0    N/A         0      Figure I.4   B05a   0 and 1    Figure I.4   B05a     0
             D6-NL       0.6    A26j        2         50     T05u      2 x 20        30      T05b      2 x 5
             D7           6     PE4-ALT    47        120     PE4D-     47            80      PE4D-      10
                                TK                           ALT                             ALT
             D8           1     PE4-ALT    47        250     PE-AQB-   47            0       –          0
             (Note)             TK                           T-ALT
             NOTE – The overall length of this loop exceeds the expected maximum length for reliable operation of ITU-T G.9701.









                                           Figure I.4 – Primary final drop loop (D5)



                                      0.6 m              60 m                     93 m
                    D1-USA   DP                                                                  NTc
                                       A26j              A26u                     A24u

                                      0.6 m               0 m                     93 m
                    D2-USA   DP                                                                  NTc
                                       A26j               - - -                   A24u

                                      0.6 m               0 m                     35 m
                    D3-UK    DP                                                                  NTc
                                     B05???               - - -                   B05a


                                      0.6 m               3 m                     70 m
                    D4-UK    DP                                                                  NTc
                                     B05???              B05u                     B05a

                                      0.6 m              50 m                    30 m
                    D6-NL    DP                                                                  NTc
                                      A26j               T05u                    T05b














                                          Figure I.5 – Illustration of final drop loops





            1056