Page 1028 - 5G Basics - Core Network Aspects
P. 1028

2                                                 Transport aspects


                                                        Annex T


                        Dynamic time assignment (DTA) – higher-layer control aspects
                                  (This annex forms an integral part of this Recommendation.)


            Editorial note: This annex was introduced by Cor.3 to ITU-T G.9701, but is not shown in revision marks for
            readability purposes.

            T.1     Scope

            This  annex  specifies  the  cross-layer  control  aspects  of  dynamic  time  assignment  (DTA).  According  to
            Annex X, the DRA block monitors traffic-related information and decides when to make changes in the TDD
            frame  configuration  of  each  FTU-O.  The  update  of  the  TDD  frame  configuration  is  done  using  the  DTA
            procedure described in clause X.6.2. This annex specifies the parameters to control the behaviour of the
            DRA functionality that determines DTA. These parameters are individual to each line managed by the DRA.


            T.2     DTA control parameters
            The following DRA control parameters facilitate DTA operation:
            •       Annex X operation mode (Annex_X_mode);
            •       Allow DTA (DTA_allowed);

            •       Handshake Mds (hs_Mds)
            •       Preferred Mds for DTA (DTA_pref_Mds);
            •       Maximum step size for DTA changes (DTA_SMax);
            •       Minimum Mds for DTA (DTA_min_Mds);
            •       Maximum Mds for DTA (DTA_max_Mds);

            •       Minimum expected throughput for DTA (DTA_ETR_min);
            •       Maximum net data rate for DTA (DTA_NDR_max);
            •       Maximum net data rate (NDR_max);
            •       Minimum expected throughput (ETR_min)
            The control parameter hs_Mds represents the Mds selected during the ITU-T G.994.1 handshake phase (see
            Table 11.70.3 of ITU-T G.994.1) and provides the number of downstream symbol periods in a TDD frame
            from the time the FTU-O enters showtime until the first DTA update. The control parameter hs_Mds is not
            specific to the application of DTA but its definition is different if DTA is enabled (see clauses T.2.7, X.6.9 and
            X.6.10).

            The  control  parameters  NDR_max  and  ETR_min  are  not  specific  to  the  application  of  DTA  but  their
            definition is different if DTA is enabled (see clauses X.6.7.6 and X.6.7.7).

            If DTA operation is disabled, these parameters shall be ignored.
            T.2.1   Annex X operation mode (Annex_X_mode)

            See clause X.6.7.1.

            T.2.2   DTA allowed (DTA_allowed)
            See clause X.6.7.2.

            T.2.3   Preferred Mds for DTA (DTA_pref_Mds)
            The  control  parameter  DTA_pref_Mds  represents  the  preferred  Mds  value  and  provides  the  number  of
            downstream symbol periods in a TDD frame requested by the DRA in a first DTA update after the FTU-O



            1018
   1023   1024   1025   1026   1027   1028   1029   1030   1031   1032   1033