-- Module SDH (G.774:02/2001)
-- See also ITU-T G.774 (02/2001)
-- See also the index of all ASN.1 assignments needed in this document
SDH {itu-t(0) recommendation(0) g(7) sdhm(774) informationModel(0)
asn1Module(2) sdh(0)} DEFINITIONS IMPLICIT TAGS ::=
BEGIN
IMPORTS
NameType -- Recommendation M.3100
FROM ASN1DefinedTypesModule {itu-t(0) recommendation(0) m(13) gnm(3100)
informationModel(0) asn1Modules(2) asn1DefinedTypeModule(0)};
g774 OBJECT IDENTIFIER ::=
{itu-t(0) recommendation(0) g(7) sdhm(774) informationModel(0)}
g774ObjectClass OBJECT IDENTIFIER ::= {g774 managedObjectClass(3)}
g774Attribute OBJECT IDENTIFIER ::= {g774 attribute(7)}
g774NameBinding OBJECT IDENTIFIER ::= {g774 nameBinding(6)}
Boolean ::= BOOLEAN
C2SignalLabel ::= INTEGER(0..255)
defaultNull Null ::= NULL
Null ::= NULL
Integer ::= INTEGER
OpticalReach ::= ENUMERATED {intraOffice(0), shortHaul(1), longHaul(2)}
OpticalWavelength ::= ENUMERATED {wl1310(0), wl1550(1)}
PathTrace ::= CHOICE {null NULL,
pathtrace [1] GraphicString
}
-- Reffering to PointerSinkType. The ENUMERATED value of invalidPointer(2)
-- should be used when a LOP condition exists or if the pointer value is unknown.
PointerSinkType ::= ENUMERATED {
normalPointer(0), concatenationIndication(1), invalidPointer(2)}
PointerSourceType ::= ENUMERATED {normalPointer(0), concatenationIndication(1)}
TrailTraceReceiveSend ::= GraphicString
V5SignalLabel ::= INTEGER(0..7)
END
-- Generated by Asnp, the ASN.1 pretty-printer of France Telecom R&D