-- GDMO definitions extracted from ITU-T Rec. G.774.4 (2001)
-- =============================================================================
connectionProtectionGroupR1 MANAGED OBJECT CLASS
DERIVED FROM "Recommendation G.774.03":protectionGroupR1;
CHARACTERIZED BY
connectionProtectionGroupPkgR1 PACKAGE
BEHAVIOUR connectionProtectionGroupR1Behaviour;
ATTRIBUTES
protectionCriteria GET-REPLACE ADD-REMOVE;
NOTIFICATIONS
"Recommendation G.774.03":protectionSwitchReportingR1
switchStatusParameter;;;
CONDITIONAL PACKAGES
holdOffTimePackage
PRESENT IF "an instance supports it";
REGISTERED AS { g774-04MObjectClass 5 } ;
connectionProtectionGroupR1Behaviour BEHAVIOUR
DEFINED AS
"This object class is used to model an automatic protection system for
subnetwork connection protection. The protectionGroupType attribute
indicates that the protection scheme used is 1+1 (plus). This object class
is a focal point for management operations and notifications related to
management of the protection system. Actual signal flow across the
subnetwork connection protection is reflected by the connectivity pointers
of the TPs involved in the subnetwork connection protection. At
instantiation time of an instance of this class the protectionCriteria
attribute is intitialized by local initial value.";
connectionProtection MANAGED OBJECT CLASS
DERIVED FROM "Recommendation G.774.03": protectionUnit;
CHARACTERIZED BY
connectionProtectionPkg PACKAGE
BEHAVIOUR connectionProtectionBehaviour;
ATTRIBUTES
switchStatus GET,
"Recommendation X.721": administrativeState GET-REPLACE,
"Recommendation X.721": operationalState GET,
"Recommendation M.3100": signalType GET,
"Recommendation M.3100": directionality GET;
NOTIFICATIONS
"Recommendation X.721": stateChange,
"Recommendation X.721": objectDeletion,
"Recommendation X.721": objectCreation;;;
REGISTERED AS { g774-04MObjectClass 2 };
connectionProtectionBehaviour BEHAVIOUR
DEFINED AS
"This object class is used to represent the assignment between an unreliable
resource (TP) and a reliable resource (TP) for the purpose of subnetwork
connection protection. This object class has properties of a
cross-connection since it represents a flexible assignment of termination
points in the context of subnetwork protection, according to Recommendation
G.803. The directionality attribute represents the type of traffic which
flows through the connection protection (CP). It can be either:
- Bidirectional - The traffic flow is passing between the unreliable and the
reliable resource in both directions.
- Unidirectional - The traffic flow is unidirectional and passing from the
unreliable to the reliable resource.
The Unreliable Resource Pointer (URP) points to one termination point which
represents one of the alternatives for the protection system. The URP points
to a TP according to the directionality of the CP, i.e.:
- the URP of a Bidirectional CP must point to a Bidirectional TP or GTP;
- the URP of an Unidirectional CP must point to a Sink TP or GTP, or to a
Bidirectional TP or GTP.
The Unreliable Resource Pointer points to Null when the corresponding
(unreliable) TP has been temporarily disconnected from the connection
protection. The crossConnectionObjectPointer of the corresponding TP points
to the connectionProtection. The Reliable Resource Pointer points either:
- to Null in the case of a Protecting Connection Protection; or
- to a Termination Point (CTP or TTP) or GTP instance that represents one
end of the subnetwork connection in the case of a protected Connection Protection.
This termination point shall have the same signal type than the CTP or GTP
representing the unreliable resource used for protection. The
crossConnectionObjectPointer of the corresponding TP points to the
connectionProtection.
The attribute Signal Type describes the signal that is cross-connected. The
termination points or GTPs that are cross-connected must have signal types
that are compatible.
If the objects listed in the Unreliable Resource Pointer and Reliable
Resource Pointer attributes are GTPs, the nth element of the Unreliable
Resource GTP is related to the nth element of the Reliable Resource GTP (for
every n). Administrative state
- Unlocked - The Connection Protection object is administratively unlocked.
Traffic is allowed to pass through the Connection Protection.
- Locked - No traffic is allowed to pass through the Connection Protection.
The traffic flow is suspended between the termination points representing
the reliable and the unreliable resources. The connectivity pointers in
the corresponding unreliable resources and reliable resources are updated
to reflect the suspension of traffic flow.
Setting the administrative state to locked does not prevent the protection
function from attempting to operate. Operational state
The operational state reflects only the connection capability of the
connection protection:
- Enabled - The Connection Protection is performing its normal
cross-connection function.
- Disabled - The Connection Protection is incapable of performing its normal
cross-connection function.
The operational state of Disabled is considered as a signal failure on the
corresponding connection and as such it must be taken into account in the
protection mechanism. The switchStatus indicates the status of the switching
requests.";
mpConnectionProtection MANAGED OBJECT CLASS
DERIVED FROM "Recommendation G.774.03": protectionUnit;
CHARACTERIZED BY
mpConnectionProtectionPkg PACKAGE
BEHAVIOUR mpConnectionProtectionBehaviour;
ATTRIBUTES
switchStatus GET,
"Recommendation X.721": administrativeState GET-REPLACE,
"Recommendation X.721": operationalState GET,
"Recommendation X.721": availabilityStatus GET,
"Recommendation M.3100": signalType GET;
NOTIFICATIONS
"Recommendation X.721": stateChange,
"Recommendation X.721": objectDeletion,
"Recommendation X.721": objectCreation;;;
REGISTERED AS { g774-04MObjectClass 3 };
mpConnectionProtectionBehaviour BEHAVIOUR
DEFINED AS
"This object class is used to represent the assignment between an unreliable
resource, which is the termination point or GTP object listed in the
Unreliable Resource Pointer attribute, and a set of reliable resources for
the purpose of protection of point-to-multipoint connection. The reliable
resources are the termination point or GTP objects listed in the To
Termination attributes of the crossConnectionmanaged objects contained by
protected mp Connection Protection.
This object class has properties of a multipoint cross-connection since its
represents a flexible assignment of termination points in the context of
subnetwork protection according to Recommendation G.803.
The Unreliable Resource Pointer (URP) points to one termination point or GTP
which represents one of the two alternatives for the protection system. The
URP must point to a Sink CTP or GTP, or to a Bidirectional TP or GTP.
The Unreliable Resource Pointer points to Null when the corresponding
(unreliable) TP has been temporarily disconnected from the multipoint
connection protection. The crossConnectionObjectPointer of the corresponding
TP points to the mpConnectionProtection.
The Reliable Resource Pointer has always the value NULL. The reliable
resources are represented by all the termination point or GTP objects
pointed to by the To Termination attribute of the crossConnection managed
objects contained by the protected mpConnectionProtection.
The attribute Signal Type describes the signal that is cross-connected. The
termination points or GTPs that are cross-connected must have signal types
that are compatible. Administrative state
- Unlocked - The Multipoint Connection Protection object is administratively
unlocked. It allows traffic to pass through each contained
cross-connection depending on its administrative state.
- Locked - No traffic is allowed to pass through the Cross-Connection
between the cross-connected termination points. The effect of this value
overrides the effect of the administrative state of each contained
cross-connection.
Setting the administrative state to locked does not prevent the protection
function from attempting to operate. Operational state
The operational state of a Multipoint Connection Protection object reflects
the overall health of the cross-connection including all the
Cross-Connection objects contained in the Multipoint Connection Protection.
- Enabled - The Cross-Connection is performing its normal function. Note
that some (but not all) of the cross-connection objects contained in the
protected Multipoint Connection Protection may be disabled.
- Disabled - The Cross-Connection is incapable of performing its normal
cross-connection function. All the cross-connection objects contained in
the protected Multipoint Connection Protection are disabled.
The operational state of Disabled is considered as a signal failure on the
corresponding connection and as such it must be taken into account in the
protection mechanism. Availability status
The supported values for this attribute are:
- Degraded - The Multipoint Connection Protection is degraded in some
respect. For instance, if one or more (but not all) Cross-Connection
objects contained in the protected Multipoint Connection Protection are
disabled, the Multipoint Connection Protection will be considered as
degraded. The Multipoint Connection Protection remains available for
service (i.e. its operational state is enabled) while it is degraded. No
automatic protection switch occurs.
- Empty SET.
The switchStatus indicates the status of the switching requests.";
sncpFabric MANAGED OBJECT CLASS
DERIVED FROM "Recommendation M.3100": fabric;
CHARACTERIZED BY
sncpFabricPackage PACKAGE
BEHAVIOUR sncpFabricBehaviour;
ACTIONS
protectUnprotect,
protectedConnect;;;
REGISTERED AS { g774-04MObjectClass 4 };
sncpFabricBehaviour BEHAVIOUR
DEFINED AS
"The subnetwork connection protection fabric object represents the function
of managing the establishment and release of protected cross-connections.";
holdOffTimePackage PACKAGE
ATTRIBUTES
holdOffTime GET-REPLACE;
REGISTERED AS { g774-04Package 1 };
holdOffTime ATTRIBUTE
WITH ATTRIBUTE SYNTAX SDHSNCPASN1.HoldOffTime;
MATCHES FOR EQUALITY;
BEHAVIOUR holdOffTimeBehaviour;
REGISTERED AS { g774-04Attribute 1 };
holdOffTimeBehaviour BEHAVIOUR
DEFINED AS
"This attribute specifies the amount of 100 ms periods which represents the
time to wait before performing a protection switch after a defect has
occurred on either the protecting or protected protection unit. The minimum
value is zero (no hold off time) and the maximum value is 100 (representing
10 seconds). The hold off time is defined in G.841.";
protectionCriteria ATTRIBUTE
WITH ATTRIBUTE SYNTAX SDHSNCPASN1.ProtectionCriteria;
MATCHES FOR EQUALITY;
BEHAVIOUR protectionCriteriaBehaviour;
REGISTERED AS { g774-04Attribute 2 };
protectionCriteriaBehaviour BEHAVIOUR
DEFINED AS
"This attribute specifies the list of configurable criteria that are to be
used for automatic switch decision supplementing those criteria which are
defined as mandatory and fixed within the SNCP function as stated in G.841. ";
switchStatus ATTRIBUTE
WITH ATTRIBUTE SYNTAX SDHSNCPASN1.ProtectionStatus;
MATCHES FOR EQUALITY;
BEHAVIOUR switchStatusBehaviour;
REGISTERED AS { g774-04Attribute 3 };
switchStatusBehaviour BEHAVIOUR
DEFINED AS
"The following is a list of all the possible status values of the
switchStatus attribute for protected connection protection or protected
mpConnectionProtection:
- No request - There is no outstanding request. An active switch hold off
time is considered a no request.
- Do Not Revert - The protected connection protection has been switched to
the protecting connection protection and the request to do so has been
subsequently cleared. This status is only applicable to 1 + 1
non-revertive systems.
- Wait-to-Restore - The protected connection protection has recovered from
an auto switch condition and the WTR timer is activated.
- Manual switch to the protecting connection protection completed - The
protected connection protection has been switched to the protecting
connection protection by a manual switch request.
- Auto switch to the protecting connection completed - The protected
connection protection has been switched to the protecting connection
protection due to an auto switch condition.
- Auto switch pending - An auto switch request cannot been completed due to
the unavailability of the protecting connection protection.
- Forced switch to the protecting connection protection completed - The
protected connection protection has been forced to switch to the
protecting connection protection.
- Forced switch to the protecting connection protection completed - auto
switch pending - An auto switch request cannot be completed due to a
completed forced switch (to protecting connection protection).
- Lockout of protected connection protection - The protected connection
protection is prevented from switching to protection.
- Lockout of protected connection protection - auto switch pending - An auto
switch request cannot be completed due to the lockout of the protected
connection protection.
The following is a list of all the possible status values of the
switchStatus attribute for protecting connection protection or protecting
mpConnectionProtection:
- No request - There is no outstanding request. An active switch hold off
time is considered a no request.
- Do Not Revert - The protected connection protection has been switched to
the protecting connection protection and the request to do so has been
cleared. This status is only applicable to 1 + 1 non-revertive systems.
- Manual switch to the protecting connection protection completed - The
protected connection protection has been switched to the protecting
connection protection by a manual switch request.
- Auto switch to the protecting connection protection completed - A
protected connection protection has been switched to the protecting
connection protection due to an auto switch condition.
- Signal fail - A signal fail condition exists on the protecting connection
protection (no traffic is being carried on the protecting connection protection).
- Forced switch to the protecting connection completed - The protected
connection protection has been forced to switch to the protecting
connection protection.
- Lockout of protection - The protecting connection protection is prevented
from providing protection.
- Lockout of protection - auto switch condition on protecting connection
protection - A lockout of protection is in place, and an auto switch
condition exists on the protecting connection protection.";
protectedConnect ACTION
BEHAVIOUR protectedConnectBehaviour;
MODE CONFIRMED;
WITH INFORMATION SYNTAX SDHSNCPASN1.ProtectedConnectInformation;
WITH REPLY SYNTAX SDHSNCPASN1.ProtectedConnectResult;
REGISTERED AS { g774-04Action 1 };
protectedConnectBehaviour BEHAVIOUR
DEFINED AS
"This action offers the capability, in a single action, to:
1) Establish a protected connection between termination points/GTPs (connect
Choice of the syntax). The connection to be established is part of a
subnetwork connection protection. The Termination Points/GTP involved in
this protected connection must not be already connected for the concerned
direction. In this case this connection establishment is done according
to the following rules:
- The protecting TP is used to describe the unreliable TP(s) of the
protecting connection. This must be done according to the description of
the protection Connection Type.
- The protection Connection Type is used to describe the type of
connection to be established, i.e. unidirectional or bidirectional. The
protection Connection Type describes the connection between the
unreliable TPs and the reliable TPs for the protected connection.
- If the protection Connection Type is bidirectional, a
connectionProtectionGroupR1 is created. The To TP part of the syntax
represents the reliable resource.
- If the protection Connection Type is unidirectional, it can concern either:
- A unidirectional point-to-point subnetwork connection protection. In
this case a connectionProtectionGroupR1 is created.
- A unidirectional point-to-multipoint subnetwork connection protection
where all legs are protected altogether. In this case a
connectionProtectionGroupR1 is created, containing:
a) the mpConnectionProtection of the working channel, connecting the
unreliable TP. The reliable TPs are connected by crossConnection
objects contained by the mpConnectionProtection.
b) the mpConnectionProtection of the protecting channel. This
mpConnectionProtection does not contain crossConnection object.
The administrative state of the created connections objects is specified as
an optional parameter of this action. If this parameter is omitted, the
administrative state will be set to 'unlocked'.
2) Add TPs/GTPs as destinations of a point-to-multipoint connection. (addLeg
Choice of the syntax).
- The legs may be added as part of the protected legs (corresponding to
the sub-choice protected Legs of the syntax). In that case each
crossConnection object corresponding to each individual leg is created,
these crossConnections are contained by the protected
mpConnectionProtection contained by the connectionProtectionGroupR1.
- The legs may be added as non-protected legs (corresponding to the
sub-choice unprotected Legs of the syntax). In that case each
crossConnection object corresponding to each individual leg is created,
these crossConnections are contained by the mpCrossConnection
representing the unprotected broadcast. If no unprotected
mpCrossConnection exists then an mpCrossConnection is created,
containing all the specified unprotected legs (if only one unprotected
leg exists, then a point-to-point unidirectional cross-connection is
created). If this action concerns an existing unidirectional
point-to-point cross-connection then a point-to-multipoint
cross-connection is created which contains the crossConnections
representing legs.
The administrative state of the created cross-connection or connection
protection objects will be the same as that of the containing multipoint
cross-connection or multipoint connection protection object unless otherwise
specified in the action parameters.
3) Connect a TP as the unreliable resource of an existing protected
connection (protected or protecting connectionProtection or
mpConnectionProtection contained in a connectionProtectionGroupR1).
(addUnreliable Choice of the syntax)
- If the specified TP is not already connected for the corresponding
direction (notConnected sub-choice of the syntax), it will be connected
by the specified connectionProtection or mpConnectionProtection.
- If the specified TP is already connected for the corresponding direction
(connected sub-choice of the syntax) by a unidirectional connection
(point-to-point or multipoint), the TP will point to the
connectionProtection or mpConnectionProtection in addition to the
existing connection(s).";
protectUnprotect ACTION
BEHAVIOUR protectUnprotectBehaviour;
MODE CONFIRMED;
WITH INFORMATION SYNTAX SDHSNCPASN1.ProtectUnprotectInformation;
WITH REPLY SYNTAX SDHSNCPASN1.ProtectedConnectResult;
REGISTERED AS { g774-04Action 2 };
protectUnprotectBehaviour BEHAVIOUR
DEFINED AS
"This action offers the capability, in a single action, to:
1) Protect an existing unprotected connection (protect Choice of the
syntax). The description for protecting an existing connection uses the
same syntax as the establishment of a new protected connection, and
follows the same rules, except that all the TPs or GTP specified in the
protectionConnectionType part must be explicitly specified by their
object instances (i.e. no tpPool, no GTP expressed by a sequence of TPs).
The connectivity specified by the protectionConnectionType part of the
syntax must reflect the same connectivity (signal flow expressed by the
connectivity pointers) as the existing one, i.e.:
- For a unidirectional point-to-point, the TP specified as the From and
the To must be already cross-connected the same way as described and
they should not be already protected for the concerned direction.
- For a bidirectional point-to-point, the TPs specified as the from and
the To must be already cross-connected the same way as described, i.e.:
a bidirectional cross-connection connecting the From TP and the To TP
(reliable TP) must already exist.
- For a point-to-multipoint, the TP specified as the From and all the TPs
specified as the To must be already cross-connected the same way and
none of them should be already part of a protection scheme for the
concerned direction. Only those legs which are specified as part of the
protectedConnect Information will be involved in the protection scheme.
A connectionProtectionGroupR1, two mpConnectionProtection's and each
crossConnection representing each leg are created as the result of this
action. If all legs are involved in the protection scheme then the
existing mpCrossConnection is deleted. The administrative state of the
new created connection objects will be the same as that of the existing
one they are to replace, unless otherwise specified in the action
parameters. The result, if OK is given by the connected Choice of the syntax.
2) Unprotect an existing protected connection (unprotect Choice of the
syntax). The description for unprotecting an existing connection uses the
same syntax as the establishment of a new unprotected connection, i.e.
the ConnectionType and ConnectionTypeBi, and follows the same rules,
except that all the described connections must already exist, and all the
TPs or GTP specified in this action must be explicitly specified by their
object instances. The connectivity specified by the syntax must reflect
the same connectivity as the existing one for either the working or the
protect part of the ConnectionProtectionGroupR1, i.e.:
- For a unidirectional point-to-point connection protection, the TP
specified as the From and the To must be respectively the unreliable TP
and the reliable TP of the (protected or protecting) connectionProtection.
- For a bidirectional point-to-point, the TPs specified as the From and
the To must be respectively the unreliable TP of either the protected or
protecting connectionProtection and the reliable TP of the protected
connectionProtection. When the choice single of the syntax is used, a
bidirectional cross-connection is created (uniform route) connecting the
specified Unreliable TP and the Reliable TP. When the choice multiple of
the syntax is used, two unidirectional cross-connections are created
(diverse route), one connecting the specified Unreliable TP to the
Reliable TP, and the other connecting the Reliable TP to the specified
Unreliable TP.
- For a point-to-multipoint, the TP specified as the From and all the TPs
specified as the To must be respectively the unreliable TP of the
protected mp Connection Protection and the To TPs of the cross-connects
contained in the mp connection protection. If TPs are specified which do
not pertain to the protection scheme, the requests fail with the logical
problem mismatching TP Instances. Only those TPs which are explicitly
specified as part of the protectedUnprotectInformation will be
unprotected, and if no mpCrossConnection was already existing then one
is created which holds each crossConnection corresponding to each
unprotected leg. If no other TP remains in the protected scheme, then
the connectionProtectionGroupR1 is deleted and consequently all its
contained objects. The administrative state of the new created
connection objects will be the same as that of the existing one they are
to replace, unless otherwise specified in the action parameters.";
switchStatusParameter PARAMETER
CONTEXT EVENT-INFO;
WITH SYNTAX SDHSNCPASN1.ProtectionStatusParameter;
BEHAVIOUR switchStatusParameterBeh;
REGISTERED AS { g774-04Parameter 1 };
switchStatusParameterBeh BEHAVIOUR
DEFINED AS
"This parameter is included in the additional info parameters of the
protection switching reporting notification. This notification is sent by
the protection group according to the following rules. There are several cases:
- The switch from protected to protecting or protecting to protected has
been done without preempting an existing switch. In this case, the old and
new values of the Switch status attribute of the protecting channel shall
be reported in the notification by means of the oldSwitchStatus and
newSwitchStatus parameters respectively.
- A switch is performed by preemting an exiting one. In this case, the old
and new values of the Switch status attribute of the protecting channel
shall be reported in the notification by means of the oldSwitchStatus and
newSwitchStatus parameters respectively.
- An auto switch condition exists on a channel but the auto switch cannot be
served due to the unavailability of the channel that otherwise protects
it. In this case the oldSwitchStatus and newSwitchStatus parameters refer
to the switch status attribute value of the channel on which the auto
switch condition arises. The exception is when the channel is already
forced or locked out, in which case no notification is sent.
- A working channel (protected unit) has been locked out or released from
lockout without modifying any existing switch. In this case the
oldSwitchStatus and newSwitchStatus parameters refer to the switch status
attribute value of the working channel which has been locked out.
- A protection channel (protecting unit) has been locked out or released
from lockout without modifying the existing switch. In this case, the
oldSwitchStatus and newSwitchStatus parameters refer to the switch status
attribute value of the protection channel which has been locked out.
The protectionSwitchReporting is not sent when the automatic switch
condition is toggling between SF and WTR condition. While in the lockout of
forced switch state no notification is sent except for ending of release failure.";
connectionProtection-connectionProtectionGroupR1 NAME BINDING
SUBORDINATE OBJECT CLASS connectionProtection AND SUBCLASSES;
NAMED BY SUPERIOR OBJECT CLASS connectionProtectionGroupR1
AND SUBCLASSES;
WITH ATTRIBUTE "Recommendation G.774.03":protectionUnitId;
BEHAVIOUR
connectionProtection-connectionProtectionGroupR1Beh BEHAVIOUR
DEFINED AS
"The connection protection is contained by a connection protection Group
managed object instance. There must be two and only two CP (Connection
Protection) in the CPG (Connection Protection Group), with the same
signal type and the same directionality. This is used to represent a
point-to-point unidirectional or bidirectional connection protection.
One of these CPs must be the protected one (protecting attribute with
the value 'FALSE'), and the other must be the protecting one (protecting
attribute with the value 'TRUE')." ;;
REGISTERED AS { g774-04NameBinding 7 };
connectionProtectionGroupR1-sncpFabric NAME BINDING
SUBORDINATE OBJECT CLASS
connectionProtectionGroupR1 AND SUBCLASSES;
NAMED BY SUPERIOR OBJECT CLASS
sncpFabric AND SUBCLASSES;
WITH ATTRIBUTE "Recommendation G.774.03":protectionGroupId;
BEHAVIOUR connectionProtectionGroupR1-sncpFabricBeh BEHAVIOUR
DEFINED AS
"A Connection Protection Group is created as the result of the
establishment of a protected connection (point-to-point or
point-to-multipoint) or of the protection of an existing non-protected
connection. When disconnecting a TP involved in a protected connection:
- if the TP is the reliable resource of a point-to-point connection
protection, or the last reliable resource (last leg) of a multipoint
connection protection, this leads to the disconnection of the
protection, resulting in the deletion of the connection protection group
and all contained objects.
- if the TP is the unreliable resource of a connection protection or
multipoint connection protection, the corresponding Unreliable Resource
Pointer is set to NULL. Such a disconnection shall be considered as a
signal failure. A new unreliable resource (TP) may be connected using
the capability to add a new unreliable resource of the protected connect
action. When both unreliable TPs are disconnected, this leads to the
disconnection of the protection, resulting in the deletion of the
connection protection group and all contained objects. ";;
REGISTERED AS { g774-04NameBinding 8 };
crossConnection-mpConnectionProtection NAME BINDING
SUBORDINATE OBJECT CLASS "Recommendation M.3100":
crossConnection AND SUBCLASSES;
NAMED BY SUPERIOR OBJECT CLASS mpConnectionProtection AND SUBCLASSES;
WITH ATTRIBUTE "Recommendation M.3100":crossConnectionId;
DELETE ONLY-IF-NO-CONTAINED-OBJECTS;
REGISTERED AS { g774-04NameBinding 3 };
crossConnection-sncpFabric NAME BINDING
SUBORDINATE OBJECT CLASS "Recommendation M.3100":
crossConnection AND SUBCLASSES;
NAMED BY SUPERIOR OBJECT CLASS sncpFabric AND SUBCLASSES;
WITH ATTRIBUTE "Recommendation M.3100":crossConnectionId;
DELETE ONLY-IF-NO-CONTAINED-OBJECTS;
REGISTERED AS { g774-04NameBinding 5 };
mpConnectionProtection-connectionProtectionGroupR1 NAME BINDING
SUBORDINATE OBJECT CLASS mpConnectionProtection AND SUBCLASSES;
NAMED BY SUPERIOR OBJECT CLASS
connectionProtectionGroupR1 AND SUBCLASSES;
WITH ATTRIBUTE "Recommendation G.774.03":protectionUnitId;
BEHAVIOUR mpConnectionProtection-connectionProtectionGroupR1Beh
BEHAVIOUR
DEFINED AS
"MultiPoint Connection Protection are created as the result of the
establishment of a protected multipoint connection or of the protection of
an existing non-protected multipoint connection. The multipoint connection
protections are contained directly by the connection protection Group
managed object instance. There must be two and only two
mpConnectionProtections in the connectionProtectionGroup, with the same
signal type. This is used to represent the point to multipoint
unidirectional connection protection.
One of these mpConnectionProtection must be the protected one (protecting
attribute with the value FALSE), and the other must be the protecting one
(protecting attribute with the value TRUE).
Only the protected mpConnectionProtection can contain cross-connections
representing the reliable resources. The configuration may be done prior
to any existing cross-connection or on an existing multipoint
cross-connection." ;;
REGISTERED AS { g774-04NameBinding 9 };
mpCrossConnection-sncpFabric NAME BINDING
SUBORDINATE OBJECT CLASS "Recommendation M.3100":
mpCrossConnection AND SUBCLASSES;
NAMED BY SUPERIOR OBJECT CLASS sncpFabric AND SUBCLASSES;
WITH ATTRIBUTE "Recommendation M.3100":mpCrossConnectionId;
REGISTERED AS { g774-04NameBinding 6 };
--<GDMO.EndDocument>--
-- =============================================================================
-- Formatted by OpenT2 Version 5.5.6.34 on Fri Aug 20 11:20:49 2004