1
Scope
2 References
3 Terms and definitions
4 Abbreviations
5 Performance management model
5.1 Overview
5.2 Requirements
6 Managed Object Classes Definitions
6.1 SDH Current Data
6.2 Regenerator Section Current Data
6.3 Regenerator Section Current Data
Threshold Reset
6.4 Path Termination Current Data
6.5 Multiplex Section Adaptation
Current Data
6.6 Regenerator Section History Data
6.7 Path Termination History Data
6.8 Multiplex Section Adaptation
History Data
7 Package definitions
7.1 Consecutive Severely Errored
Second Current Data Package
7.2 Far End Consecutive Severely
Errored Second Current Data Package
7.3 Far End Current Data Package
7.4 Far End History Data Package
7.5 History Package
7.6 Threshold Reset Package
7.7 Unavailable Second Current Data
Package
7.8 Unavailable Second History Data
Package
7.9 Unavailable Time Alarm Package
8 Attributes definitions
8.1 Consecutive Severely Errored
Second Event
8.2 Errored Second
8.3 Far End Errored Second
8.4 Far End Background Block Error
8.5 Far End Consecutive Severely
Errored Second Event
8.6 Number of Consecutive Severely
Errored Second
8.7 Background Block Error
8.8 Severely Errored Seconds
8.9 Far End Severely Errored Seconds
8.10 Unavailable Seconds
9
Actions
10 Notifications
11 Parameters
12 Name binding definitions
12.1 History Data – SDH Current Data
12.2 Path Termination Current Data – VC4 TTP
SinkR1
12.3 Path Termination Current Data –
VC3 TTP SinkR1
12.4 Path Termination Current Data –
VC2 TTP SinkR1
12.5 Path Termination Current Data –
VC12 TTP SinkR1
12.6 Path Termination Current Data –
VC11 TTP SinkR1
13 Subordination rules
14 Pointer constraints
15 Supporting ASN.1 productions
Appendix I – Inheritance and naming diagram
Appendix II – Threshold Reset (TR) Behaviour
Appendix III – Managed object classes moved to ITU-T
G.774.6
III.1 rsCurrentData
III.2 rsCurrentDataTR
III.3 rsHistoryData
III.4 msAdaptationCurrentData
III.5 msAdaptationHistoryData
Appendix IV – Functionality that is no longer required
IV.1 Managed object class definitions
IV.1.1 Electrical Source Synchronous Physical Interface Current Data
IV.1.2 Optical Source Synchronous Physical Interface Current Data
IV.1.3 Multiplex Section Current Data
IV.1.4 Multiplex Section Current Data Threshold Reset
IV.1.5 Protection Current Data
IV.1.6 Path Termination Current Data Threshold Reset
IV.1.7 Electrical Synchronous Physical Interface
History Data
IV.1.8 Optical Synchronous Physical Interface History Data
IV.1.9 Multiplex Section History Data
IV.1.10 Protection History Data
IV.2 Package definitions
IV.2.1 Laser Bias Current Data Package
IV.2.2 Laser Bias Tide Mark Package
IV.2.3 Laser Temperature Current Data Package
IV.2.4 Laser Temperature Tide Mark Package
IV.2.5 Transmit Power Level Current Data Package
IV.2.6 Transmit Power Level Tide Mark Package
IV.3 Attributes definitions
IV.3.1 Laser Bias
IV.3.2 Laser Bias
Tide Mark Maximum
IV.3.3 Laser Bias Tide Mark Minimum
IV.3.4 Laser Temperature
IV.3.5 Laser Temperature Tide Mark Maximum
IV.3.6 Laser Temperature Tide Mark Minimum
IV.3.7 Protection Switch Count
IV.3.8 Protection Switch Duration
IV.3.9 Transmit Power Level
IV.3.10 Transmit Power Level Tide Mark Maximum
IV.3.11 Transmit Power Level Tide Mark
Minimum
IV.4 Name binding definitions
IV.4.1 MS Current Data – MS TTP Sink
IV.4.2 MS Current Data Threshold Reset – MS TTP Sink
IV.4.3 MS Current Data – Protected TTP Sink
IV.4.4 MS Current Data Threshold Reset – Protected TTP Sink
IV.4.5 Protection Current Data – Protection Unit
IV.4.6 Path Termination Current Data Threshold Reset – VC4 TTP SinkR1
IV.4.7 Path Termination Current Data Threshold Reset – VC3 TTP SinkR1
IV.4.8 Path Termination Current Data Threshold Reset – VC2 TTP SinkR1
IV.4.9 Path Termination Current Data
Threshold Reset – VC12 TTP SinkR1
IV.4.10 Path Termination Current Data Threshold Reset – VC11 TTP SinkR1
IV.4.11 Electrical Source SPI Current Data – Electrical SPITTP Source
IV.4.12 Optical Source
SPI Current Data – Optical SPITTP Source