<!-- ITU-T H.810 CERTIFIED THERMOMETER DATA OUTPUT IN HL7 R2 MESSAGE FORMAT -->
<section>
 <templateId root="2.16.840.1.113883.10.20.1.7"/>
 <templateId root="2.16.840.1.113883.10.20.9.1"/>
 <code code="46264-8" codeSystem="2.16.840.1.113883.6.1"/><!--LOINC code 46264-8 “Medical Equipment” -->
 <title>Medical Equipment</title>
 <text>
	<!-- Device information -->
	<table border="1" width="100%">
		<tbody>
			<tr>
				<th>System Type</th>
				<th>System Model</th>
				<th>System Manufacturer</th>
				<th>System ID</th>
				<th>Production Spec</th>
				<th>Regulated</th>
			</tr>
			<tr>
				<td>Blood Pressure Monitor</td>
				<td>Pulse Master 2000</td>
				<td>Acme</td>
				<td>1F-3E-46-78-9A-BC-DE-F1</td>
				<td>
					 Unspecified:
						Serial Number: 584216<br/>
						Part Number: 69854<br/>
						Hardware Revision: 2.1<br/>
						Software Revision: 1.1<br/>
						Protocol Revision: 1.0<br/>
						Prod Spec GMDN:
				</td>
				<td>Regulated</td>
			</tr>
		</tbody>
	</table>
 </text>
 <entry typeCode="COMP">
	<organizer classCode="CLUSTER" moodCode="EVN">
		<templateId root="2.16.840.1.113883.10.20.9.4"/>
		<statusCode code="completed"/>
		<effectiveTime value="20080801104033-0600"/><!-- 2008/08/01 10:40:33 -->
		<participant typeCode="SBJ">
			<participantRole classCode="MANU">
				<templateId root="2.16.840.1.113883.10.20.1.52"/>
				<templateId root="2.16.840.1.113883.10.20.9.9"/>
				<id root="1.2.840.10004.1.1.1.0.0.1.0.0.1.2680" assigningAuthorityName="EUI-64" extension="1A-34-46-78-9A-BC-DE-F3"/><!-- Unique Identifier (IMEI) -->
				<code nullFlavor="OTH">
					<originalText>Regulated Device</originalText>
				</code>
				<playingDevice>
					<code code="MDC_DEV_SPEC_PROFILE_BPM" codeSystem="2.16.840.1.113883.6.24" codeSystemName="MDC" displayName="Blood Pressure Monitor"><!-- ISO/IEEE 11073 MDC_DEV_SPEC_PROFILE_BPM "Blood Pressure Monitor" -->
						<translation code="32033000" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Arterial pressure monitor"/><!-- SNOMED code 32033000 “Arterial Pressure Monitor -->
						<translation code="???" codeSystem="GMDN-OID">
							<!-- move Production spec GMDN here from the manufacturerModelName-->
						</translation>
					</code>
<code code="MDC_DEV_SPEC_PROFILE_BPM" codeSystem="2.16.840.1.113883.6.24" codeSystemName="MDC" displayName="Blood Pressure Monitor"><!-- ISO/IEEE 11073 MDC_DEV_SPEC_PROFILE_BPM "Blood Pressure Monitor" -->
						<translation code="32033000" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Arterial pressure monitor"/><!-- SNOMED code 32033000 “Arterial Pressure Monitor -->
						</translation>
					</code>
					<manufacturerModelName>
						<!-- these will be unstructured, the text below is an example (no shalls for the labels used below)-->
						Model: Pulse Master 2000
						Serial number:584216
						Part number: 69854
						Hardware revision: 2.1
						Software revision: 1.1
						Protocol revision: 1.0
						Unspecified (free text comment):
					</manufacturerModelName>
				</playingDevice>
				<scopingEntity>
					<desc>Acme</desc>
				</scopingEntity>
			</participantRole>
		</participant>
		<component>
			<observation classCode="OBS" moodCode="EVN">
				<!--... all our device observations go here -->
				<code/>
			</observation>
		</component>
	</organizer>
 </entry>
</section>
<!-- Observation information -->
<section>
 <templateId root="2.16.840.1.113883.10.20.1.16"/>
 <templateId root="2.16.840.1.113883.10.20.9.2"/>
 <code code="8716-3" codeSystem="2.16.840.1.113883.6.1"/><!-- LOINC code 8716-3 “Vital Signs” -->
 <title>Vital Signs</title>
 <text>
	<paragraph>Thermometer Results</paragraph>
	<table border="1" width="100%">
		<tBody>
			<tr>
				<th>Date/Time</th>
				<th>Body Temp</th>
				<th>Finger Temp</th>
				<th>Oral Temp</th>
			</tr>
			<tr>
				<td>20080501104033</td>
				<td>99.9 deg F</td>
				<td>88.8 deg F</td>
				<td>37.5 deg C</td>
			</tr>
		</tBody>
	</table>
 </text>
 <entry typeCode="DRIV">
	<organizer classCode="CLUSTER" moodCode="EVN">
		<!-- Vital sign data/ Test Groups -->
		<!-- A VITAL SIGNS ORGANIZER IS USED TO GROUP RELATED -->
		<templateId root="2.16.840.1.113883.10.20.1.35"/>
		<id root="b606a959-baab-4836-84a8-97c4e9857533"/>
		<code code="46680005" codeSystem="2.16.840.1.113883.6.96" displayName="Vital signs"/><!-- SNOMED code 46680005 “Vital Signs” -->
		<statusCode code="completed"/>
		<component>
			<observation classCode="OBS" moodCode="EVN">
				<templateId root="2.16.840.1.113883.10.20.1.31"/>
				<id root="975c2f3b-2bd4-4e45-aed1-84af9ff51b10"/>
				<code code="386725007" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Body Temperature"><!-- SNOMED code 386725007 “Body Temperature” -->
					<translation code="MDC_TEMP_BODY" codeSystem="2.16.840.1.113883.6.24" codeSystemName="MDC" displayName="Body Temperature"/><!-- ISO/IEEE 11073 MDC_TEMP_BODY "Body Temperature" -->
				</code>
				<statusCode code="completed"/>
				<effectiveTime value="20080501104033-0600"/><!—2008/05/01 10:40:33 -->
				<value xsi:type="PQ" value="99.9" unit="[degF]"/><!—99.9 F -->
				<participant typeCode="DEV">
					<participantRole>
				<id root="1.2.840.10004.1.1.1.0.0.1.0.0.1.2680" assigningAuthorityName="EUI-64" extension="1A-34-46-78-9A-BC-DE-F3"/>
					</participantRole>
				</participant>
			</observation>
		</component>
		<component>
			<observation classCode="OBS" moodCode="EVN">
				<templateId root="2.16.840.1.113883.10.20.1.31"/>
				<templateId root="2.16.840.1.113883.10.20.9.8"/>
				<id root="975c2f3b-2bd4-4e45-aed1-84af9ff51b10"/>
				<code code="433588001" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Temperature of digit of hand"><!-- SNOMED code 433588001 “Temperature of digit of hand” -->
					<translation code="MDC_TEMP_FINGER" codeSystem="2.16.840.1.113883.6.24" codeSystemName="MDC" displayName="Finger Temperature"/> "/><!-- ISO/IEEE 11073 MDC_TEMP_FINGER "Finger Temperature" -->
				</code>
				<statusCode code="completed"/>
				<effectiveTime value="20080501104033-0600"/><!—2008/05/01 10:40:33 -->
				<value xsi:type="PQ" value="88.8" unit="[degF]"/><!—88.8 F -->
				<participant typeCode="DEV">
					<participantRole>
				<id root="1.2.840.10004.1.1.1.0.0.1.0.0.1.2680" assigningAuthorityName="EUI-64" extension="1A-34-46-78-9A-BC-DE-F3"/>
					</participantRole>
				</participant>
			</observation>
			</component>
		<component>
			<observation classCode="OBS" moodCode="EVN">
				<templateId root="2.16.840.1.113883.10.20.1.31"/>
				<templateId root="2.16.840.1.113883.10.20.9.8"/>
				<id root="975c2f3b-2bd4-4e45-aed1-84af9ff51b10"/>
					<code code="415945006" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Oral Temperature"><!-- SNOMED code 415945006 “Oral Temperature” -->
						<translation code="MDC_TEMP_ORAL" codeSystem="2.16.840.1.113883.6.24" codeSystemName="MDC" displayName="Oral Temperature"/><!-- ISO/IEEE 11073 MDC_TEMP_ORAL "Oral Temperature" -->
					</code>
				<statusCode code="completed"/>
				<effectiveTime value="20080501104033-0600"/><!—2008/05/01 10:40:33 -->
				<value xsi:type="PQ" value="37.5" unit="Cel"/><!—37.5 C -->
				<participant typeCode="DEV">
					<participantRole>
				<id root="1.2.840.10004.1.1.1.0.0.1.0.0.1.2680" assigningAuthorityName="EUI-64" extension="1A-34-46-78-9A-BC-DE-F3"/>
					</participantRole>
				</participant>
			</observation>
		</component>
	</organizer>
 </entry>
</section>