CONTENTS

 1     Scope
 2     References
 3     Definitions
 4     Abbreviations
 5     Test System Architecture and flows
 6     Line test components
        6.1     Common line tests components for ANSI, ITU-T and TTC
                  6.1.1     Quiet termination test component
                  6.1.2     Loopback line test response
        6.2     ITU-T line tests components
                  6.2.1     ITU-T 404 Hz line test package
                  6.2.2     ITU-T 816 Hz line test package
                  6.2.3     ITU-T 1020 Hz line test package
                  6.2.4     ITU-T 2100 Hz disable tone line test package
                  6.2.5     ITU-T 2100 Hz disable echo canceller tone line test package
                  6.2.6     ITU-T 2804 Hz tone line test package
                  6.2.7     ITU-T noise test tone line test package
                  6.2.8     ITU-T digital pseudo random test tone line test package
                  6.2.9     ITU-T ATME No. 2 test line response package
        6.3     ANSI line test components
                  6.3.1     ANSI 1004 Hz test tone line test package
                  6.3.2     ANSI test responder line test package
                  6.3.3     ANSI 2225 Hz test progress tone line test package
                  6.3.4     ANSI digital test signal line test package
                  6.3.5     ANSI inverting loopback line test response
        6.4     TTC line test components
 7     Line test procedures at the testing switching centre
        7.1     ITU-T
                  7.1.1     Test line types according to ITU-T Rec. O.11
                  7.1.2     Automatic testing measuring equipment according to ITU-T Rec. O.22
        7.2     ANSI
                  7.2.1     100-type test lines – Quiet termination 5.1.1.1/T1.207-2000
                  7.2.2     100-type test lines – 1000 Hz (milliwatt) Test tone 5.1.1.2/T1.207-2000
                  7.2.3     101-type test line – Communications 5.1.2/T1.207-2000
                  7.2.4     102-type test line – Milliwatt 5.1.3/T1.207-2000
                  7.2.5     104-type test line 5.1.4/T1.207-2000
                  7.2.6     105-type test line – Automatic transmission measuring 5.1.5/T1.207-2000
                  7.2.7     107-type line test – Data transmission test line 5.1.6/T1.207-2000
                  7.2.8     109-test line – Echo canceller testing 5.17/T1.207-2000
                  7.2.9     108-type test line – Digital non inverting loop-back 5.2.1/T1.207-2000
                 7.2.10     606-type test line – Digital inverting loop-back 5.2.2/T1.207-2000
                 7.2.11     Operational line tests 5.3/T1.207-2000
        7.3     TTC line tests
 8     Line test procedures at the testee switching centre
        8.1     ITU-T
                  8.1.1     Test line types according to ITU-T Rec. O.11
                  8.1.2     Automatic testing measuring equipment according to ITU-T Rec. O.22
        8.2     ANSI
                  8.2.1     100-type test lines – Quiet termination 5.1.1.1/T1.207-2000
                  8.2.2     100-type test lines – 1000 Hz (milliwatt) test tone 5.1.1.2/T1.207-2000
                  8.2.3     101-type test line – Communications 5.1.2/T1.207-2000
                  8.2.4     102-type test line – Milliwatt 5.1.3/T1.207-2000
                  8.2.5     104-type test line 5.1.4/T1.207-2000
                  8.2.6     105-type test line – Automatic transmission measuring 5.1.5/T1.207-2000
                  8.2.7     107-type test line – Data transmission test line 5.1.6/T1.207-2000
                  8.2.8     109-test line – Echo canceller testing 5.1.7/T1.207-2000
                  8.2.9     108-type test line – Digital non inverting loop-back 5.2.1/T1.207-2000
                 8.2.10     606-type test line – Digital inverting loop-back 5.2.2/T1.207-2000
                 8.2.11     Operational line tests 5.3/T1.207-2000
        8.3     TTC line tests
                  8.3.1     TTC Standard JJ-90-10 Ver4, common interface for intercarrier (Appendix A)