<?xml version="1.0" encoding="ISO-8859-1"?>
<rss version="2.0"><channel><title>ITU-T K  Series Recommendations: New Documents</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K&amp;type=newitems</link><description>Recently Posted Recommendations</description><language>en</language><lastBuildDate>mer, 17 jan 2012 14:50:07 GMT</lastBuildDate><managingEditor>tsbedh@itu.int</managingEditor><webMaster>webmaster@itu.int</webMaster><category>Recommendations</category><image><title>ITU-T K  Series Recommendations</title><url>http://www.itu.int/res/templates/v1.0/images/logo_ituw.gif</url><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K&amp;type=products&amp;lang=e</link></image><item><title>[ K.20 (11/88) ] - Resistibility of telecommunication switching equipment to overvoltages and overcurrents</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.20-198811-S&amp;type=items</link><description>Resistibility of telecommunication switching equipment to overvoltages and overcurrents&lt;BR/&gt;</description><pubDate>mer, 17 jan 2012 13:39:30 GMT</pubDate><guid isPermaLink="false">T-REC-K.20-198811-S!!PDF-E</guid></item><item><title>[ K.20 (11/88) ] - Resistibility of telecommunication switching equipment to overvoltages and overcurrents</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.20-198811-S&amp;type=items</link><description>Resistibility of telecommunication switching equipment to overvoltages and overcurrents&lt;BR/&gt;</description><pubDate>mer, 17 jan 2012 13:39:30 GMT</pubDate><guid isPermaLink="false">T-REC-K.20-198811-S!!MSW-E</guid></item><item><title>[ K.25 (11/88) ] - Lightning protection of optical fibre cables</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.25-198811-S&amp;type=items</link><description>Lightning protection of optical fibre cables&lt;BR/&gt;</description><pubDate>jeu, 11 jan 2012 14:22:10 GMT</pubDate><guid isPermaLink="false">T-REC-K.25-198811-S!!PDF-E</guid></item><item><title>[ K.25 (11/88) ] - Lightning protection of optical fibre cables</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.25-198811-S&amp;type=items</link><description>Lightning protection of optical fibre cables&lt;BR/&gt;</description><pubDate>jeu, 11 jan 2012 14:22:10 GMT</pubDate><guid isPermaLink="false">T-REC-K.25-198811-S!!MSW-E</guid></item><item><title>[ K.22 (11/88) ] - Overvoltage resistibility of equipment connected to an ISDN T/S bus</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.22-198811-S&amp;type=items</link><description>Overvoltage resistibility of equipment connected to an ISDN T/S bus&lt;BR/&gt;</description><pubDate>jeu, 11 jan 2012 14:20:59 GMT</pubDate><guid isPermaLink="false">T-REC-K.22-198811-S!!PDF-E</guid></item><item><title>[ K.22 (11/88) ] - Overvoltage resistibility of equipment connected to an ISDN T/S bus</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.22-198811-S&amp;type=items</link><description>Overvoltage resistibility of equipment connected to an ISDN T/S bus&lt;BR/&gt;</description><pubDate>jeu, 11 jan 2012 14:20:59 GMT</pubDate><guid isPermaLink="false">T-REC-K.22-198811-S!!MSW-E</guid></item><item><title>[ K.21 (11/88) ] - Resistibility of subscribers' terminals to overvoltages and overcurrents</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.21-198811-S&amp;type=items</link><description>Resistibility of subscribers' terminals to overvoltages and overcurrents&lt;BR/&gt;</description><pubDate>jeu, 11 jan 2012 14:19:13 GMT</pubDate><guid isPermaLink="false">T-REC-K.21-198811-S!!PDF-E</guid></item><item><title>[ K.21 (11/88) ] - Resistibility of subscribers' terminals to overvoltages and overcurrents</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.21-198811-S&amp;type=items</link><description>Resistibility of subscribers' terminals to overvoltages and overcurrents&lt;BR/&gt;</description><pubDate>jeu, 11 jan 2012 14:19:12 GMT</pubDate><guid isPermaLink="false">T-REC-K.21-198811-S!!MSW-E</guid></item><item><title>[ K.12 (11/88) ] - Characteristics of gas discharge tubes for the protection of telecommunications installations</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.12-198811-S&amp;type=items</link><description>Characteristics of gas discharge tubes for the protection of telecommunications installations&lt;BR/&gt;</description><pubDate>jeu, 11 jan 2012 14:18:08 GMT</pubDate><guid isPermaLink="false">T-REC-K.12-198811-S!!PDF-E</guid></item><item><title>[ K.12 (11/88) ] - Characteristics of gas discharge tubes for the protection of telecommunications installations</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.12-198811-S&amp;type=items</link><description>Characteristics of gas discharge tubes for the protection of telecommunications installations&lt;BR/&gt;</description><pubDate>jeu, 11 jan 2012 14:18:08 GMT</pubDate><guid isPermaLink="false">T-REC-K.12-198811-S!!MSW-E</guid></item><item><title>[ K.11 (11/88) ] - Principles of protection against overvoltages and overcurrents</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.11-198811-S&amp;type=items</link><description>Principles of protection against overvoltages and overcurrents&lt;BR/&gt;</description><pubDate>jeu, 11 jan 2012 14:16:30 GMT</pubDate><guid isPermaLink="false">T-REC-K.11-198811-S!!PDF-E</guid></item><item><title>[ K.11 (11/88) ] - Principles of protection against overvoltages and overcurrents</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.11-198811-S&amp;type=items</link><description>Principles of protection against overvoltages and overcurrents&lt;BR/&gt;</description><pubDate>jeu, 11 jan 2012 14:16:30 GMT</pubDate><guid isPermaLink="false">T-REC-K.11-198811-S!!MSW-E</guid></item><item><title>[ K.10 (11/88) ] - Unbalance about earth of telecommunication installations</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.10-198811-S&amp;type=items</link><description>Unbalance about earth of telecommunication installations&lt;BR/&gt;</description><pubDate>jeu, 11 jan 2012 14:15:13 GMT</pubDate><guid isPermaLink="false">T-REC-K.10-198811-S!!PDF-E</guid></item><item><title>[ K.10 (11/88) ] - Unbalance about earth of telecommunication installations</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.10-198811-S&amp;type=items</link><description>Unbalance about earth of telecommunication installations&lt;BR/&gt;</description><pubDate>jeu, 11 jan 2012 14:15:12 GMT</pubDate><guid isPermaLink="false">T-REC-K.10-198811-S!!MSW-E</guid></item><item><title>[ K.83 (03/11) ] - Monitoring of electromagnetic field levels</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.83-201103-I&amp;type=items</link><description>&lt;BR/&gt;&lt;font color='red'&gt;The edition posted on 25 July 2011 did not reflect the correct title. That edition was removed and a corrected edition was posted on 20 December 2011.&lt;/font&gt;

&lt;div class=WordSection1&gt;

&lt;table class=MsoNormalTable border=0 cellspacing=0 cellpadding=0 width="100%"
 style='border-collapse:collapse'&gt;
 &lt;tr&gt;
  &lt;td width="100%" valign=top style='width:100.0%;padding:0cm 5.4pt 0cm 5.4pt'&gt;
  &lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;a name=isume&gt;Summary&lt;/a&gt;&lt;/h3&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Recommendation ITU-T K.83 gives guidance
  on how to make long-term measurements for the monitoring of electromagnetic
  fields (EMF) in the selected areas that are under public concern, in order to
  show that EMFs are under control and under the limits. The purpose of this
  Recommendation is to provide for the general public clear and easily
  available data concerning electromagnetic field levels in the form of results
  of continuous measurement.&lt;/span&gt;&lt;/p&gt;
  &lt;/td&gt;
 &lt;/tr&gt;
&lt;/table&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>mer, 20 déc 2011 15:45:01 GMT</pubDate><guid isPermaLink="false">T-REC-K.83-201103-I!!PDF-E</guid></item><item><title>[ K.83 (03/11) ] - Monitoring of electromagnetic field levels</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.83-201103-I&amp;type=items</link><description>&lt;BR/&gt;&lt;font color='red'&gt;The edition posted on 25 July 2011 did not reflect the correct title. That edition was removed and a corrected edition was posted on 20 December 2011.&lt;/font&gt;

&lt;div class=WordSection1&gt;

&lt;table class=MsoNormalTable border=0 cellspacing=0 cellpadding=0 width="100%"
 style='border-collapse:collapse'&gt;
 &lt;tr&gt;
  &lt;td width="100%" valign=top style='width:100.0%;padding:0cm 5.4pt 0cm 5.4pt'&gt;
  &lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;a name=isume&gt;Summary&lt;/a&gt;&lt;/h3&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Recommendation ITU-T K.83 gives guidance
  on how to make long-term measurements for the monitoring of electromagnetic
  fields (EMF) in the selected areas that are under public concern, in order to
  show that EMFs are under control and under the limits. The purpose of this
  Recommendation is to provide for the general public clear and easily
  available data concerning electromagnetic field levels in the form of results
  of continuous measurement.&lt;/span&gt;&lt;/p&gt;
  &lt;/td&gt;
 &lt;/tr&gt;
&lt;/table&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>mer, 20 déc 2011 15:45:01 GMT</pubDate><guid isPermaLink="false">T-REC-K.83-201103-I!!MSW-E</guid></item><item><title>[ K.20 (11/11) ] - Resistibility of telecommunication equipment installed in a telecommunications centre to overvoltages and overcurrents</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.20-201111-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;Summary&lt;/h3&gt;

&lt;p class=MsoNormal&gt;Recommendation ITU-T K.20 specifies resistibility
requirements and test procedures for telecommunication equipment that is
installed in a telecommunication centre.&lt;/p&gt;

&lt;p class=MsoNormal&gt;Overvoltages or overcurrents covered by this Recommendation
include surges due to lightning on or near the line plant, short&amp;#8209;term
induction from adjacent a.c. power lines or railway systems, earth potential
rise due to power faults, direct contacts between telecommunication lines and
power lines and electrostatic discharges. The sources for overvoltages in
internal lines, between equipment/racks, are mainly inductive coupling caused
by lightning currents being conducted in nearby lightning strokes or lightning
currents being conducted in nearby conductors.&lt;/p&gt;

&lt;p class=MsoNormal&gt;Major changes compared with the 2008 version of this
Recommendation include:&lt;/p&gt;

&lt;p class=enumlev1&gt;.          updating the references;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          information on what USB ports should be tested;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          information on when to add protection to untested
ports;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          adding test requirements for external coaxial
cable ports;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          adding test requirements for multiple conductor
internal unshielded cable ports.&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 25 nov 2011 15:32:46 GMT</pubDate><guid isPermaLink="false">T-REC-K.20-201111-P!!MSW-E</guid></item><item><title>[ K.20 (11/11) ] - Resistibility of telecommunication equipment installed in a telecommunications centre to overvoltages and overcurrents</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.20-201111-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;Summary&lt;/h3&gt;

&lt;p class=MsoNormal&gt;Recommendation ITU-T K.20 specifies resistibility
requirements and test procedures for telecommunication equipment that is
installed in a telecommunication centre.&lt;/p&gt;

&lt;p class=MsoNormal&gt;Overvoltages or overcurrents covered by this Recommendation
include surges due to lightning on or near the line plant, short&amp;#8209;term
induction from adjacent a.c. power lines or railway systems, earth potential
rise due to power faults, direct contacts between telecommunication lines and
power lines and electrostatic discharges. The sources for overvoltages in
internal lines, between equipment/racks, are mainly inductive coupling caused
by lightning currents being conducted in nearby lightning strokes or lightning
currents being conducted in nearby conductors.&lt;/p&gt;

&lt;p class=MsoNormal&gt;Major changes compared with the 2008 version of this
Recommendation include:&lt;/p&gt;

&lt;p class=enumlev1&gt;.          updating the references;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          information on what USB ports should be tested;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          information on when to add protection to untested
ports;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          adding test requirements for external coaxial
cable ports;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          adding test requirements for multiple conductor
internal unshielded cable ports.&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 25 nov 2011 15:32:46 GMT</pubDate><guid isPermaLink="false">T-REC-K.20-201111-P!!PDF-E</guid></item><item><title>[ K.87 (11/11) ] - Guide for the application of electromagnetic security requirements - Basic Recommendation</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.87-201111-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;span lang=EN-GB&gt;Summary&lt;/span&gt;&lt;/h3&gt;

&lt;p class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;&lt;span
lang=EN-GB&gt;General guidelines of information security management for telecommunications
organizations are presented in ITU-T Recommendation X.1051, which is based on
ISO/IEC Standards 27001 and 27002. In an information security management system
(ISMS) based on Recommendation X.1051, physical security is a key issue, as
shown for example in the following text presented in Recommendation X.1051:&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;&lt;i&gt;&lt;span
lang=EN-GB&gt;"A site whose environment is least susceptible to damage from strong
electromagnetic field shall be selected for communication centers.&lt;/span&gt;&lt;/i&gt;&lt;span
lang=EN-GB&gt; &lt;i&gt;If necessary, less than satisfactory site may be selected
provided appropriate measures are taken to protect telecommunications equipment
rooms with electromagnetic shields, etc."&lt;/i&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;&lt;i&gt;&lt;span
lang=EN-GB&gt;"controls should be adopted to minimize the risk of potential
physical threats, e.g. theft, fire, explosives, smoke, water (or water supply
failure), dust, vibration, chemical effects, electrical supply interference,
communications interference, electromagnetic radiation, and vandalism;"&lt;/span&gt;&lt;/i&gt;&lt;/p&gt;

&lt;p class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;&lt;span
lang=EN-GB&gt;When the security is managed considering above mentioned sentences,
we should evaluate the threat and mitigate equipment or site. The threat is
related to "Vulnerability" and "Confidentiality" in ISMS.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;&lt;span
lang=EN-GB&gt;This basic Recommendation outlines electromagnetic security risks of
telecommunication equipments and guides how to assess and prevent those risks,
in order to manage ISMS in accordance with Recommendation X.1051. Major
electromagnetic security risks taken up in this Recommendation are as follows:&lt;/span&gt;&lt;/p&gt;

&lt;ul style='margin-top:0cm' type=disc&gt;
 &lt;li class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;Natural
     EM threats (e.g. lightning);&lt;/li&gt;
 &lt;li class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;Unintentional
     interference (i.e. Electromagnetic Interference (EMI));&lt;/li&gt;
 &lt;li class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;Intentional
     interference(i.e. Intentional Electromagnetic Interference (IEMI));&lt;/li&gt;
 &lt;li class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;Deliberate
     EM attack via High Altitude Electromagnetic Pulse (HEMP);&lt;/li&gt;
 &lt;li class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;Deliberate
     EM attack via High Power Electromagnetic (HPEM);&lt;/li&gt;
 &lt;li class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;Information
     leakage from EM&lt;span lang=EN-GB&gt; emanation (i.e. &lt;/span&gt;E&lt;span lang=EN-GB&gt;lectromagnetic&lt;/span&gt;&lt;span
     lang=EN-GB&gt; &lt;/span&gt;&lt;span lang=EN-GB&gt;security (EMSEC))&lt;/span&gt;;&lt;/li&gt;
&lt;/ul&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 25 nov 2011 15:30:57 GMT</pubDate><guid isPermaLink="false">T-REC-K.87-201111-P!!MSW-E</guid></item><item><title>[ K.87 (11/11) ] - Guide for the application of electromagnetic security requirements - Basic Recommendation</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.87-201111-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;span lang=EN-GB&gt;Summary&lt;/span&gt;&lt;/h3&gt;

&lt;p class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;&lt;span
lang=EN-GB&gt;General guidelines of information security management for telecommunications
organizations are presented in ITU-T Recommendation X.1051, which is based on
ISO/IEC Standards 27001 and 27002. In an information security management system
(ISMS) based on Recommendation X.1051, physical security is a key issue, as
shown for example in the following text presented in Recommendation X.1051:&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;&lt;i&gt;&lt;span
lang=EN-GB&gt;"A site whose environment is least susceptible to damage from strong
electromagnetic field shall be selected for communication centers.&lt;/span&gt;&lt;/i&gt;&lt;span
lang=EN-GB&gt; &lt;i&gt;If necessary, less than satisfactory site may be selected
provided appropriate measures are taken to protect telecommunications equipment
rooms with electromagnetic shields, etc."&lt;/i&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;&lt;i&gt;&lt;span
lang=EN-GB&gt;"controls should be adopted to minimize the risk of potential
physical threats, e.g. theft, fire, explosives, smoke, water (or water supply
failure), dust, vibration, chemical effects, electrical supply interference,
communications interference, electromagnetic radiation, and vandalism;"&lt;/span&gt;&lt;/i&gt;&lt;/p&gt;

&lt;p class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;&lt;span
lang=EN-GB&gt;When the security is managed considering above mentioned sentences,
we should evaluate the threat and mitigate equipment or site. The threat is
related to "Vulnerability" and "Confidentiality" in ISMS.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;&lt;span
lang=EN-GB&gt;This basic Recommendation outlines electromagnetic security risks of
telecommunication equipments and guides how to assess and prevent those risks,
in order to manage ISMS in accordance with Recommendation X.1051. Major
electromagnetic security risks taken up in this Recommendation are as follows:&lt;/span&gt;&lt;/p&gt;

&lt;ul style='margin-top:0cm' type=disc&gt;
 &lt;li class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;Natural
     EM threats (e.g. lightning);&lt;/li&gt;
 &lt;li class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;Unintentional
     interference (i.e. Electromagnetic Interference (EMI));&lt;/li&gt;
 &lt;li class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;Intentional
     interference(i.e. Intentional Electromagnetic Interference (IEMI));&lt;/li&gt;
 &lt;li class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;Deliberate
     EM attack via High Altitude Electromagnetic Pulse (HEMP);&lt;/li&gt;
 &lt;li class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;Deliberate
     EM attack via High Power Electromagnetic (HPEM);&lt;/li&gt;
 &lt;li class=MsoNormal style='text-align:justify;text-justify:inter-ideograph'&gt;Information
     leakage from EM&lt;span lang=EN-GB&gt; emanation (i.e. &lt;/span&gt;E&lt;span lang=EN-GB&gt;lectromagnetic&lt;/span&gt;&lt;span
     lang=EN-GB&gt; &lt;/span&gt;&lt;span lang=EN-GB&gt;security (EMSEC))&lt;/span&gt;;&lt;/li&gt;
&lt;/ul&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 25 nov 2011 15:30:57 GMT</pubDate><guid isPermaLink="false">T-REC-K.87-201111-P!!PDF-E</guid></item><item><title>[ K.45 (11/11) ] - Resistibility of telecommunication equipment installed in the access and trunk networks to overvoltages and overcurrents</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.45-201111-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;Summary&lt;/h3&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Recommendation ITU-T K.45 specifies
resistibility requirements and test procedures for telecommunication equipment
installed between telecommunication centres and between a telecommunication
centre and customer's premises building.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Overvoltages or overcurrents covered by
this Recommendation include surges due to lightning on or near the line plant,
short-term induction from adjacent a.c. power lines or railway systems, earth
potential rise due to power faults, direct contact between telecommunication
lines and power lines and electrostatic discharges.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Major changes compared with the 2008
version of this Recommendation include:&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;.          &lt;/span&gt;updating the references;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          information on when to add protection to untested
ports;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          adding test requirements for external coaxial
cable ports;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 25 nov 2011 15:29:52 GMT</pubDate><guid isPermaLink="false">T-REC-K.45-201111-P!!MSW-E</guid></item><item><title>[ K.45 (11/11) ] - Resistibility of telecommunication equipment installed in the access and trunk networks to overvoltages and overcurrents</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.45-201111-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;Summary&lt;/h3&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Recommendation ITU-T K.45 specifies
resistibility requirements and test procedures for telecommunication equipment
installed between telecommunication centres and between a telecommunication
centre and customer's premises building.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Overvoltages or overcurrents covered by
this Recommendation include surges due to lightning on or near the line plant,
short-term induction from adjacent a.c. power lines or railway systems, earth
potential rise due to power faults, direct contact between telecommunication
lines and power lines and electrostatic discharges.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Major changes compared with the 2008
version of this Recommendation include:&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;.          &lt;/span&gt;updating the references;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          information on when to add protection to untested
ports;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          adding test requirements for external coaxial
cable ports;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 25 nov 2011 15:29:52 GMT</pubDate><guid isPermaLink="false">T-REC-K.45-201111-P!!PDF-E</guid></item><item><title>[ K.85 (11/11) ] - Requirements for the mitigation of lightning effects on home networks installed in customer premises</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.85-201111-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;a name="_Toc241922917"&gt;&lt;span
lang=EN-GB&gt;Summary&lt;/span&gt;&lt;/a&gt;&lt;/h3&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;This recommendation gives the requirements
for Home Network equipment and installations in customer premises. It covers the
classification of interfaces, resistibility of equipment, impact of
installation practices, installation of SPDs and a risk assessment of equipment
damage according to [IEC 62305-2]. The risk assessment of user injury will be
covered by a separate recommendation.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 25 nov 2011 15:28:44 GMT</pubDate><guid isPermaLink="false">T-REC-K.85-201111-P!!MSW-E</guid></item><item><title>[ K.85 (11/11) ] - Requirements for the mitigation of lightning effects on home networks installed in customer premises</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.85-201111-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;a name="_Toc241922917"&gt;&lt;span
lang=EN-GB&gt;Summary&lt;/span&gt;&lt;/a&gt;&lt;/h3&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;This recommendation gives the requirements
for Home Network equipment and installations in customer premises. It covers the
classification of interfaces, resistibility of equipment, impact of
installation practices, installation of SPDs and a risk assessment of equipment
damage according to [IEC 62305-2]. The risk assessment of user injury will be
covered by a separate recommendation.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 25 nov 2011 15:28:44 GMT</pubDate><guid isPermaLink="false">T-REC-K.85-201111-P!!PDF-E</guid></item><item><title>[ K.88 (11/11) ] - EMC requirements for Next Generation Network equipment</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.88-201111-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;span lang=EN-GB&gt;Summary&lt;/span&gt;&lt;/h3&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;This Recommendation specifies the emission
and immunity requirements for next generation network equipment, based on IP
packet technologies. It also describes operational conditions for emission and
immunity testing. Performance criteria for immunity tests are also specified.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 25 nov 2011 15:27:33 GMT</pubDate><guid isPermaLink="false">T-REC-K.88-201111-P!!MSW-E</guid></item><item><title>[ K.88 (11/11) ] - EMC requirements for Next Generation Network equipment</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.88-201111-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;span lang=EN-GB&gt;Summary&lt;/span&gt;&lt;/h3&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;This Recommendation specifies the emission
and immunity requirements for next generation network equipment, based on IP
packet technologies. It also describes operational conditions for emission and
immunity testing. Performance criteria for immunity tests are also specified.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 25 nov 2011 15:27:33 GMT</pubDate><guid isPermaLink="false">T-REC-K.88-201111-P!!PDF-E</guid></item><item><title>[ K.21 (11/11) ] - Resistibility of telecommunication equipment installed in customer premises to overvoltages and overcurrents</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.21-201111-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;Summary&lt;/h3&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Recommendation ITU-T K.21 specifies
resistibility requirements and test procedures for telecommunication equipment
that is installed in or on a customer premises building.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Overvoltages or overcurrents covered by
this Recommendation include surges due to lightning on or near the line plant,
short-term induction from adjacent a.c. power lines or railway systems, earth
potential rise due to power faults, direct contacts between telecommunication
lines and power lines and electrostatic discharges. The sources for
overvoltages in internal lines are mainly inductive coupling caused by
lightning currents being conducted in nearby lightning strokes or lightning
currents being conducted in nearby conductors.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Major changes compared with the 2008
version of this Recommendation include: &lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          updating the references;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          information on what USB ports should be tested;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          information on when to add protection to untested
ports;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          adding test requirements for external coaxial
cable ports;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          adding test requirements for multiple conductor
internal unshielded cable ports.&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 25 nov 2011 15:26:26 GMT</pubDate><guid isPermaLink="false">T-REC-K.21-201111-P!!MSW-E</guid></item><item><title>[ K.21 (11/11) ] - Resistibility of telecommunication equipment installed in customer premises to overvoltages and overcurrents</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.21-201111-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;Summary&lt;/h3&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Recommendation ITU-T K.21 specifies
resistibility requirements and test procedures for telecommunication equipment
that is installed in or on a customer premises building.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Overvoltages or overcurrents covered by
this Recommendation include surges due to lightning on or near the line plant,
short-term induction from adjacent a.c. power lines or railway systems, earth
potential rise due to power faults, direct contacts between telecommunication
lines and power lines and electrostatic discharges. The sources for
overvoltages in internal lines are mainly inductive coupling caused by
lightning currents being conducted in nearby lightning strokes or lightning
currents being conducted in nearby conductors.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Major changes compared with the 2008
version of this Recommendation include: &lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          updating the references;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          information on what USB ports should be tested;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          information on when to add protection to untested
ports;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          adding test requirements for external coaxial
cable ports;&lt;/p&gt;

&lt;p class=enumlev1&gt;.          adding test requirements for multiple conductor
internal unshielded cable ports.&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 25 nov 2011 15:26:26 GMT</pubDate><guid isPermaLink="false">T-REC-K.21-201111-P!!PDF-E</guid></item><item><title>[ K.44 (11/11) ] - Resistibility tests for telecommunication equipment exposed to overvoltages and overcurrents - Basic Recommendation</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.44-201111-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;Summary&lt;/h3&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Recommendation ITU-T K.44 seeks to
establish fundamental test methods and criteria for the resistibility of
telecommunication equipment to overvoltages and overcurrents.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Overvoltages or overcurrents covered by
this Recommendation include surges due to lightning on or near the line plant,
short-term induction of alternating voltages from adjacent electric power lines
or electrified railway systems, earth potential rise due to power faults, and
direct contacts between telecommunication lines and power lines.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Major changes compared with the 2008 version
of this Recommendation include:&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;-           &lt;/span&gt;updating the references;&lt;/p&gt;

&lt;p class=enumlev1&gt;.            amended Criterion A;&lt;/p&gt;

&lt;p class=enumlev1&gt;.            revision of the test schematics to improve
clarity;&lt;/p&gt;

&lt;p class=enumlev1&gt;.            adding test schematics for external coaxial
cable ports;&lt;/p&gt;

&lt;p class=enumlev1&gt;.            adding multi conductor test schematics for
internal unshielded cables;&lt;/p&gt;

&lt;p class=enumlev1&gt;.            adding tolerances for waveform generation.&lt;/p&gt;

&lt;p class=enumlev1&gt;.            &lt;span lang=EN-GB&gt;addition of ports that rely on
insulation coordination for surge protection.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 25 nov 2011 15:25:18 GMT</pubDate><guid isPermaLink="false">T-REC-K.44-201111-P!!MSW-E</guid></item><item><title>[ K.44 (11/11) ] - Resistibility tests for telecommunication equipment exposed to overvoltages and overcurrents - Basic Recommendation</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.44-201111-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;Summary&lt;/h3&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Recommendation ITU-T K.44 seeks to
establish fundamental test methods and criteria for the resistibility of
telecommunication equipment to overvoltages and overcurrents.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Overvoltages or overcurrents covered by
this Recommendation include surges due to lightning on or near the line plant,
short-term induction of alternating voltages from adjacent electric power lines
or electrified railway systems, earth potential rise due to power faults, and
direct contacts between telecommunication lines and power lines.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Major changes compared with the 2008 version
of this Recommendation include:&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;-           &lt;/span&gt;updating the references;&lt;/p&gt;

&lt;p class=enumlev1&gt;.            amended Criterion A;&lt;/p&gt;

&lt;p class=enumlev1&gt;.            revision of the test schematics to improve
clarity;&lt;/p&gt;

&lt;p class=enumlev1&gt;.            adding test schematics for external coaxial
cable ports;&lt;/p&gt;

&lt;p class=enumlev1&gt;.            adding multi conductor test schematics for
internal unshielded cables;&lt;/p&gt;

&lt;p class=enumlev1&gt;.            adding tolerances for waveform generation.&lt;/p&gt;

&lt;p class=enumlev1&gt;.            &lt;span lang=EN-GB&gt;addition of ports that rely on
insulation coordination for surge protection.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 25 nov 2011 15:25:18 GMT</pubDate><guid isPermaLink="false">T-REC-K.44-201111-P!!PDF-E</guid></item><item><title>[ K.86 (11/11) ] - Method for measuring Longitudinal Conversion Loss (9kHz - 30MHz)</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.86-201111-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;span lang=EN-GB&gt;Summary&lt;/span&gt;&lt;/h3&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;With the liberalization in
telecommunications, unbundling becomes common-place in telecommunications
networks. The unbundling of the access network increases the number of
operators that may provide services within a common access network cable. In
this context, unbalance is not only related to the transmission performance of
the services, but also strongly related to EMC performance of the services. The
LCL of telecommunication lines or telecommunication ports is a &lt;/span&gt;measure
of the degree of &lt;span lang=EN-GB&gt;unwanted transverse signal produced at the
terminals of the network due to the presence of a&lt;/span&gt;&lt;span lang=EN-GB&gt; &lt;/span&gt;&lt;span
lang=EN-GB&gt;longitudinal signal on the connecting leads.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Considering the frequency range of
broadband services such as ISDN, ADSL, ADSL2, ADSL2plus, VDSL and VDSL2, this
Recommendation presents the method for measuring Longitudinal Conversion Loss for
the frequency range from 9kHz to 30MHz and presents the suggestion of the admissible
value for the unbundling condition.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 25 nov 2011 15:21:21 GMT</pubDate><guid isPermaLink="false">T-REC-K.86-201111-P!!MSW-E</guid></item><item><title>[ K.86 (11/11) ] - Method for measuring Longitudinal Conversion Loss (9kHz - 30MHz)</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.86-201111-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;span lang=EN-GB&gt;Summary&lt;/span&gt;&lt;/h3&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;With the liberalization in
telecommunications, unbundling becomes common-place in telecommunications
networks. The unbundling of the access network increases the number of
operators that may provide services within a common access network cable. In
this context, unbalance is not only related to the transmission performance of
the services, but also strongly related to EMC performance of the services. The
LCL of telecommunication lines or telecommunication ports is a &lt;/span&gt;measure
of the degree of &lt;span lang=EN-GB&gt;unwanted transverse signal produced at the
terminals of the network due to the presence of a&lt;/span&gt;&lt;span lang=EN-GB&gt; &lt;/span&gt;&lt;span
lang=EN-GB&gt;longitudinal signal on the connecting leads.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Considering the frequency range of
broadband services such as ISDN, ADSL, ADSL2, ADSL2plus, VDSL and VDSL2, this
Recommendation presents the method for measuring Longitudinal Conversion Loss for
the frequency range from 9kHz to 30MHz and presents the suggestion of the admissible
value for the unbundling condition.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 25 nov 2011 15:21:21 GMT</pubDate><guid isPermaLink="false">T-REC-K.86-201111-P!!PDF-E</guid></item><item><title>[ K.70 (2007) Amendment 2 (05/11) ] - Appendix I - New version v.2.0.0 of the software EMF estimator</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.70-201105-I!Amd2&amp;type=items</link><description>Appendix I - New version v.2.0.0 of the software EMF estimator&lt;BR/&gt;</description><pubDate>sam, 22 jui 2011 13:16:11 GMT</pubDate><guid isPermaLink="false">T-REC-K.70-201105-I!Amd2!SOFT-ZST-E</guid></item><item><title>[ K.77 (2009) Corrigendum 1 (05/11) ]</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.77-201105-I!Cor1&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;table class=MsoNormalTable border=0 cellspacing=0 cellpadding=0 width="100%"
 style='border-collapse:collapse'&gt;
 &lt;tr&gt;
  &lt;td width="100%" valign=top style='width:100.0%;padding:0cm 5.4pt 0cm 5.4pt'&gt;
  &lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;a name=isume&gt;Summary&lt;/a&gt;&lt;/h3&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Corrigendum 1 to Recommendation ITU-T
  K.77 corrects reference defects given in Recommendation ITU-T K.77 (2009).
  One reference has been withdrawn and merged with another reference. The
  reference and its associated text reference are changed. Other references are
  removed as they are not stated in the body of this Recommendation. Six
  references have been revised and their references are updated.&lt;/span&gt;&lt;/p&gt;
  &lt;/td&gt;
 &lt;/tr&gt;
&lt;/table&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>ven, 14 jui 2011 10:27:11 GMT</pubDate><guid isPermaLink="false">T-REC-K.77-201105-I!Cor1!MSW-E</guid></item><item><title>[ K.77 (2009) Corrigendum 1 (05/11) ]</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.77-201105-I!Cor1&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;table class=MsoNormalTable border=0 cellspacing=0 cellpadding=0 width="100%"
 style='border-collapse:collapse'&gt;
 &lt;tr&gt;
  &lt;td width="100%" valign=top style='width:100.0%;padding:0cm 5.4pt 0cm 5.4pt'&gt;
  &lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;a name=isume&gt;Summary&lt;/a&gt;&lt;/h3&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Corrigendum 1 to Recommendation ITU-T
  K.77 corrects reference defects given in Recommendation ITU-T K.77 (2009).
  One reference has been withdrawn and merged with another reference. The
  reference and its associated text reference are changed. Other references are
  removed as they are not stated in the body of this Recommendation. Six
  references have been revised and their references are updated.&lt;/span&gt;&lt;/p&gt;
  &lt;/td&gt;
 &lt;/tr&gt;
&lt;/table&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>ven, 14 jui 2011 10:27:11 GMT</pubDate><guid isPermaLink="false">T-REC-K.77-201105-I!Cor1!PDF-E</guid></item><item><title>[ K.72 (06/11) ] - Protection of telecommunication lines using metallic conductors against lightning - Risk management</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.72-201106-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;table class=MsoNormalTable border=0 cellspacing=0 cellpadding=0 width="100%"
 style='border-collapse:collapse'&gt;
 &lt;tr&gt;
  &lt;td width="100%" valign=top style='width:100.0%;padding:0cm 5.4pt 0cm 5.4pt'&gt;
  &lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;a name=isume&gt;Summary&lt;/a&gt;&lt;/h3&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Recommendation ITU-T K.72 gives the
  methodology for evaluating the need for protection measures against lightning
  of telecommunication lines using metallic conductors. &lt;/span&gt;&lt;/p&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;This method is based on the risk
  assessment: protection measures are necessary when the risk is greater than
  the tolerable risk. Maximum value of the tolerable risks is suggested.&lt;/span&gt;&lt;/p&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;This Recommendation considers the risk of
  loss of service of the telecommunication network. &lt;/span&gt;&lt;/p&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;The risk is evaluated through the risk
  components caused by lightning, which is the source of damage on
  telecommunication line as a function of the striking point with respect to
  the telecommunication line (lightning flashes direct to the line, near the
  line, or directly to the structures connected at the ends of the line).&lt;/span&gt;&lt;/p&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;This Recommendation shall be used
  together with Recommendation ITU-T&amp;nbsp;K.47, which provides the risk
  assessment and the protection measures against lightning flashes direct to
  the telecommunication line and connected structures, and
  Recommendation&amp;nbsp;ITU-T&amp;nbsp;K.46, which provides the risk assessment and
  the protection measures against lightning flashes near the telecommunication
  line.&lt;/span&gt;&lt;/p&gt;
  &lt;/td&gt;
 &lt;/tr&gt;
&lt;/table&gt;

&lt;p class=MsoNormal align=center style='text-align:center'&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 17 jui 2011 14:39:08 GMT</pubDate><guid isPermaLink="false">T-REC-K.72-201106-P!!MSW-E</guid></item><item><title>[ K.72 (06/11) ] - Protection of telecommunication lines using metallic conductors against lightning - Risk management</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.72-201106-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;table class=MsoNormalTable border=0 cellspacing=0 cellpadding=0 width="100%"
 style='border-collapse:collapse'&gt;
 &lt;tr&gt;
  &lt;td width="100%" valign=top style='width:100.0%;padding:0cm 5.4pt 0cm 5.4pt'&gt;
  &lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;a name=isume&gt;Summary&lt;/a&gt;&lt;/h3&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Recommendation ITU-T K.72 gives the
  methodology for evaluating the need for protection measures against lightning
  of telecommunication lines using metallic conductors. &lt;/span&gt;&lt;/p&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;This method is based on the risk
  assessment: protection measures are necessary when the risk is greater than
  the tolerable risk. Maximum value of the tolerable risks is suggested.&lt;/span&gt;&lt;/p&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;This Recommendation considers the risk of
  loss of service of the telecommunication network. &lt;/span&gt;&lt;/p&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;The risk is evaluated through the risk
  components caused by lightning, which is the source of damage on
  telecommunication line as a function of the striking point with respect to
  the telecommunication line (lightning flashes direct to the line, near the
  line, or directly to the structures connected at the ends of the line).&lt;/span&gt;&lt;/p&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;This Recommendation shall be used
  together with Recommendation ITU-T&amp;nbsp;K.47, which provides the risk
  assessment and the protection measures against lightning flashes direct to
  the telecommunication line and connected structures, and
  Recommendation&amp;nbsp;ITU-T&amp;nbsp;K.46, which provides the risk assessment and
  the protection measures against lightning flashes near the telecommunication
  line.&lt;/span&gt;&lt;/p&gt;
  &lt;/td&gt;
 &lt;/tr&gt;
&lt;/table&gt;

&lt;p class=MsoNormal align=center style='text-align:center'&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 17 jui 2011 14:39:08 GMT</pubDate><guid isPermaLink="false">T-REC-K.72-201106-P!!PDF-E</guid></item><item><title>[ K.71 (06/11) ] - Protection of customer antenna installations</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.71-201106-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;span lang=EN-GB&gt;Summary&lt;/span&gt;&lt;/h3&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;ITU-T Recommendation K.71 provides
information to network operators on when antennas may be installed in, or on, a
customer building without performing a building-specific risk assessment. &lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;When a risk assessment is required, the
Recommendation provides guidance on the application of IEC 62305-2. It also
provides information on the responsibilities of the network operator and the building
owner.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;This revised version of Recommendation K.71
has updated references and added definitions from IEC 60364-5-54 to minimise
confusion regarding protective conductors. The section on protecting against
contacts between the antenna and feeder cable has been amended. Appendix II has
been checked to ensure the generic risk assessments are in line with IEC
62305-2 ed. 2&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 17 jui 2011 14:37:41 GMT</pubDate><guid isPermaLink="false">T-REC-K.71-201106-P!!MSW-E</guid></item><item><title>[ K.71 (06/11) ] - Protection of customer antenna installations</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.71-201106-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;span lang=EN-GB&gt;Summary&lt;/span&gt;&lt;/h3&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;ITU-T Recommendation K.71 provides
information to network operators on when antennas may be installed in, or on, a
customer building without performing a building-specific risk assessment. &lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;When a risk assessment is required, the
Recommendation provides guidance on the application of IEC 62305-2. It also
provides information on the responsibilities of the network operator and the building
owner.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;This revised version of Recommendation K.71
has updated references and added definitions from IEC 60364-5-54 to minimise
confusion regarding protective conductors. The section on protecting against
contacts between the antenna and feeder cable has been amended. Appendix II has
been checked to ensure the generic risk assessments are in line with IEC
62305-2 ed. 2&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 17 jui 2011 14:37:41 GMT</pubDate><guid isPermaLink="false">T-REC-K.71-201106-P!!PDF-E</guid></item><item><title>[ K.66 (06/11) ] - Protection of customer premises from overvoltages</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.66-201106-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;a name=isume&gt;&lt;span lang=EN-GB&gt;Summary&lt;/span&gt;&lt;/a&gt;&lt;/h3&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;This Recommendation:&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;.            provides recommendations for
bonding and earthing of telecommunication equipment in residential and
commercial customer premises;&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;.            refers to [ITU-T K.21] for
equipment resistibility requirements;&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;.            recommends earthing and bonding
requirements to coordinate with the resistibility requirements of [ITU-T K.21] and
the safety requirements of [IEC&amp;nbsp;60950-1] and [IEC&amp;nbsp;62368].;&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;.            recommends the installation practices
for bonding of all services and the installation of SPDs;&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;.            illustrates problems associated
with earthing and bonding and provides solutions for these earthing and bonding
problems. These include:&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev2&gt;&lt;span lang=EN-GB&gt;1)   methods to improve the earthing and
bonding;&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev2&gt;&lt;span lang=EN-GB&gt;2)   methods of providing additional
protection external to the equipment;&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev2&gt;&lt;span lang=EN-GB&gt;3)   special resistibility and safety
requirements;&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;.            recommends responsibilities for
protection at customer premises;&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;.            refers to [IEC 62305-3] for
protection against direct lightning.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;This revision of K.66 includes an update of
the references and a revision of section 6.3 to include more information on
preventing equipment damage. Appendix IV, containing information on Special
resistibility requirements has been deleted. The reader is directed to [ITU-T
K.44].&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 17 jui 2011 14:31:05 GMT</pubDate><guid isPermaLink="false">T-REC-K.66-201106-P!!MSW-E</guid></item><item><title>[ K.66 (06/11) ] - Protection of customer premises from overvoltages</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.66-201106-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;a name=isume&gt;&lt;span lang=EN-GB&gt;Summary&lt;/span&gt;&lt;/a&gt;&lt;/h3&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;This Recommendation:&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;.            provides recommendations for
bonding and earthing of telecommunication equipment in residential and
commercial customer premises;&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;.            refers to [ITU-T K.21] for
equipment resistibility requirements;&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;.            recommends earthing and bonding
requirements to coordinate with the resistibility requirements of [ITU-T K.21] and
the safety requirements of [IEC&amp;nbsp;60950-1] and [IEC&amp;nbsp;62368].;&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;.            recommends the installation practices
for bonding of all services and the installation of SPDs;&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;.            illustrates problems associated
with earthing and bonding and provides solutions for these earthing and bonding
problems. These include:&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev2&gt;&lt;span lang=EN-GB&gt;1)   methods to improve the earthing and
bonding;&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev2&gt;&lt;span lang=EN-GB&gt;2)   methods of providing additional
protection external to the equipment;&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev2&gt;&lt;span lang=EN-GB&gt;3)   special resistibility and safety
requirements;&lt;/span&gt;&lt;/p&gt;

&lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;.            recommends responsibilities for
protection at customer premises;&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;.            refers to [IEC 62305-3] for
protection against direct lightning.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;This revision of K.66 includes an update of
the references and a revision of section 6.3 to include more information on
preventing equipment damage. Appendix IV, containing information on Special
resistibility requirements has been deleted. The reader is directed to [ITU-T
K.44].&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 17 jui 2011 14:31:05 GMT</pubDate><guid isPermaLink="false">T-REC-K.66-201106-P!!PDF-E</guid></item><item><title>[ K.65 (01/11) ] - Overvoltage and overcurrent requirements for termination modules with contacts for test ports or surge protective devices</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.65-201101-I&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;table class=MsoNormalTable border=0 cellspacing=0 cellpadding=0 width="100%"
 style='border-collapse:collapse'&gt;
 &lt;tr&gt;
  &lt;td width="100%" valign=top style='width:100.0%;padding:0cm 5.4pt 0cm 5.4pt'&gt;
  &lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;a name=isume&gt;Summary&lt;/a&gt;&lt;/h3&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Recommendation ITU-T K.65 specifies the
  overvoltage requirements and test procedures for termination modules, with
  contacts for test ports or surge protective devices (SPDs), used for
  symmetric pair conductors subjected to overvoltages and overcurrents.&lt;/span&gt;&lt;/p&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Overvoltages or overcurrents covered by
  this Recommendation include surges due to lightning on or near the line
  plant, short-term induction of alternating voltages from adjacent power lines
  or railway systems, earth potential rise due to power faults, and direct
  contacts between telecommunication lines and power lines.&lt;/span&gt;&lt;/p&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Major changes compared with the 2004
  version of this Recommendation include:&lt;/span&gt;&lt;/p&gt;
  &lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;-          the addition of a mains contact
  test to the equipment side of a module with series elements;&lt;/span&gt;&lt;/p&gt;
  &lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;-          a reduction of the current magnitude
  for test Figure C.2 and for the customer side test for test Figure C.3 (tests
  2.2 and 2.3);&lt;/span&gt;&lt;/p&gt;
  &lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;-          a revision of Figure &lt;/span&gt;E.1
  - 10/350 µs current generator to be in line with Recommendation&amp;nbsp;ITU-T K.44,
  &lt;span lang=EN-AU&gt;Figure II.4-1 - 10/350 &amp;#956;s current surge generator;&lt;/span&gt;&lt;/p&gt;
  &lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;-          the addition of information &lt;/span&gt;on
  the use of fail-safes;&lt;/p&gt;
  &lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;-          the addition of a coordination &lt;/span&gt;test,
  for modules with series elements, to check that surges under the firing
  voltage of the gas discharge tube (GDT) will not damage the series elements;&lt;/p&gt;
  &lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;-          the addition of a &lt;/span&gt;high
  voltage a.c. test to simulate a voltage &amp;gt; 230 V a.c. which will operate a
  600 V GDT.&lt;/p&gt;
  &lt;/td&gt;
 &lt;/tr&gt;
&lt;/table&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>ven, 05 mai 2011 09:41:33 GMT</pubDate><guid isPermaLink="false">T-REC-K.65-201101-I!!MSW-E</guid></item><item><title>[ K.65 (01/11) ] - Overvoltage and overcurrent requirements for termination modules with contacts for test ports or surge protective devices</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.65-201101-I&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;table class=MsoNormalTable border=0 cellspacing=0 cellpadding=0 width="100%"
 style='border-collapse:collapse'&gt;
 &lt;tr&gt;
  &lt;td width="100%" valign=top style='width:100.0%;padding:0cm 5.4pt 0cm 5.4pt'&gt;
  &lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;a name=isume&gt;Summary&lt;/a&gt;&lt;/h3&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Recommendation ITU-T K.65 specifies the
  overvoltage requirements and test procedures for termination modules, with
  contacts for test ports or surge protective devices (SPDs), used for
  symmetric pair conductors subjected to overvoltages and overcurrents.&lt;/span&gt;&lt;/p&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Overvoltages or overcurrents covered by
  this Recommendation include surges due to lightning on or near the line
  plant, short-term induction of alternating voltages from adjacent power lines
  or railway systems, earth potential rise due to power faults, and direct
  contacts between telecommunication lines and power lines.&lt;/span&gt;&lt;/p&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Major changes compared with the 2004
  version of this Recommendation include:&lt;/span&gt;&lt;/p&gt;
  &lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;-          the addition of a mains contact
  test to the equipment side of a module with series elements;&lt;/span&gt;&lt;/p&gt;
  &lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;-          a reduction of the current magnitude
  for test Figure C.2 and for the customer side test for test Figure C.3 (tests
  2.2 and 2.3);&lt;/span&gt;&lt;/p&gt;
  &lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;-          a revision of Figure &lt;/span&gt;E.1
  - 10/350 µs current generator to be in line with Recommendation&amp;nbsp;ITU-T K.44,
  &lt;span lang=EN-AU&gt;Figure II.4-1 - 10/350 &amp;#956;s current surge generator;&lt;/span&gt;&lt;/p&gt;
  &lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;-          the addition of information &lt;/span&gt;on
  the use of fail-safes;&lt;/p&gt;
  &lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;-          the addition of a coordination &lt;/span&gt;test,
  for modules with series elements, to check that surges under the firing
  voltage of the gas discharge tube (GDT) will not damage the series elements;&lt;/p&gt;
  &lt;p class=enumlev1&gt;&lt;span lang=EN-GB&gt;-          the addition of a &lt;/span&gt;high
  voltage a.c. test to simulate a voltage &amp;gt; 230 V a.c. which will operate a
  600 V GDT.&lt;/p&gt;
  &lt;/td&gt;
 &lt;/tr&gt;
&lt;/table&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>ven, 05 mai 2011 09:41:33 GMT</pubDate><guid isPermaLink="false">T-REC-K.65-201101-I!!PDF-E</guid></item><item><title>[ K.64 (01/11) ] - Safe working practices for outside equipment installed in particular environments</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.64-201101-I&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;table class=MsoNormalTable border=0 cellspacing=0 cellpadding=0 width="100%"
 style='border-collapse:collapse'&gt;
 &lt;tr&gt;
  &lt;td width="100%" valign=top style='width:100.0%;padding:0cm 5.4pt 0cm 5.4pt'&gt;
  &lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;a name=isume&gt;&lt;span lang=EN-GB&gt;Summary&lt;/span&gt;&lt;/a&gt;&lt;/h3&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Recommendation ITU-T K.64 describes
  working practices for service personnel to help them work safely in telecommunication
  installations in three specific environments. &lt;/span&gt;&lt;/p&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;The specific environments covered in this
  Recommendation are characterized by wet conditions or close proximity to
  exposed metallic parts.  &lt;/span&gt;&lt;/p&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;The working practices apply to
  telecommunication plants with voltage levels higher than the limits defined
  for analogue PSTN circuits&lt;/span&gt;&lt;span lang=EN-GB&gt;, such as remote feeding
  telecommunication current or voltage (RFT-C or RFT-V) circuits.&lt;/span&gt;&lt;/p&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;This version of Recommendation&amp;nbsp;ITU-T
  K.64 includes a warning regarding contact with terminals carrying RFT
  circuits with small parts of the body, e.g., back of the hand. The references
  have been updated.&lt;/span&gt;&lt;/p&gt;
  &lt;/td&gt;
 &lt;/tr&gt;
&lt;/table&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>ven, 05 mai 2011 09:34:15 GMT</pubDate><guid isPermaLink="false">T-REC-K.64-201101-I!!MSW-E</guid></item><item><title>[ K.64 (01/11) ] - Safe working practices for outside equipment installed in particular environments</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.64-201101-I&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;table class=MsoNormalTable border=0 cellspacing=0 cellpadding=0 width="100%"
 style='border-collapse:collapse'&gt;
 &lt;tr&gt;
  &lt;td width="100%" valign=top style='width:100.0%;padding:0cm 5.4pt 0cm 5.4pt'&gt;
  &lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;a name=isume&gt;&lt;span lang=EN-GB&gt;Summary&lt;/span&gt;&lt;/a&gt;&lt;/h3&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Recommendation ITU-T K.64 describes
  working practices for service personnel to help them work safely in telecommunication
  installations in three specific environments. &lt;/span&gt;&lt;/p&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;The specific environments covered in this
  Recommendation are characterized by wet conditions or close proximity to
  exposed metallic parts.  &lt;/span&gt;&lt;/p&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;The working practices apply to
  telecommunication plants with voltage levels higher than the limits defined
  for analogue PSTN circuits&lt;/span&gt;&lt;span lang=EN-GB&gt;, such as remote feeding
  telecommunication current or voltage (RFT-C or RFT-V) circuits.&lt;/span&gt;&lt;/p&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;This version of Recommendation&amp;nbsp;ITU-T
  K.64 includes a warning regarding contact with terminals carrying RFT
  circuits with small parts of the body, e.g., back of the hand. The references
  have been updated.&lt;/span&gt;&lt;/p&gt;
  &lt;/td&gt;
 &lt;/tr&gt;
&lt;/table&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>ven, 05 mai 2011 09:34:15 GMT</pubDate><guid isPermaLink="false">T-REC-K.64-201101-I!!PDF-E</guid></item><item><title>[ K.84 (01/11) ] - Test methods and guide against information leaks through unintentional electromagnetic emissions</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.84-201101-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 align=left style='margin-left:0cm;text-align:left;text-indent:0cm'&gt;&lt;span
lang=EN-GB&gt;Summary&lt;/span&gt;&lt;/h3&gt;

&lt;p class=MsoNormal style='text-indent:14.15pt'&gt;&lt;span lang=EN-GB&gt;In an
information security management system (ISMS), based on Recommendation &lt;br&gt;
ITU-T X.1051 and ISO/IEC Standards 27001 and 27002, physical security is a key
issue.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal style='text-indent:14.15pt'&gt;&lt;span lang=EN-GB
style='color:black'&gt;When security is managed taking the above references into
consideration, we should evaluate the threats and mitigate their impact against
equipment or sites. Threats are related to confidentiality in ISMS.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal style='text-indent:14.15pt'&gt;&lt;span lang=EN-GB
style='color:black'&gt;This recommendation describes threats from information
leakage due to unintentional electromagnetic emanations, and the two approaches
of mitigation i.e reduction of emission from equipment and the level of site
shielding are described. Information leakage test methods for conducted and
radiated emission are presented. &lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 21 jan 2011 10:06:41 GMT</pubDate><guid isPermaLink="false">T-REC-K.84-201101-P!!PDF-E</guid></item><item><title>[ K.84 (01/11) ] - Test methods and guide against information leaks through unintentional electromagnetic emissions</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.84-201101-P&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;h3 align=left style='margin-left:0cm;text-align:left;text-indent:0cm'&gt;&lt;span
lang=EN-GB&gt;Summary&lt;/span&gt;&lt;/h3&gt;

&lt;p class=MsoNormal style='text-indent:14.15pt'&gt;&lt;span lang=EN-GB&gt;In an
information security management system (ISMS), based on Recommendation &lt;br&gt;
ITU-T X.1051 and ISO/IEC Standards 27001 and 27002, physical security is a key
issue.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal style='text-indent:14.15pt'&gt;&lt;span lang=EN-GB
style='color:black'&gt;When security is managed taking the above references into
consideration, we should evaluate the threats and mitigate their impact against
equipment or sites. Threats are related to confidentiality in ISMS.&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal style='text-indent:14.15pt'&gt;&lt;span lang=EN-GB
style='color:black'&gt;This recommendation describes threats from information
leakage due to unintentional electromagnetic emanations, and the two approaches
of mitigation i.e reduction of emission from equipment and the level of site
shielding are described. Information leakage test methods for conducted and
radiated emission are presented. &lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>sam, 21 jan 2011 10:06:40 GMT</pubDate><guid isPermaLink="false">T-REC-K.84-201101-P!!MSW-E</guid></item><item><title>[ K.82 (05/10) ] - Characteristics and ratings of solid-state, self-restoring overcurrent protectors for the protection of telecommunications installations</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.82-201005-I&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;table class=MsoNormalTable border=0 cellspacing=0 cellpadding=0 width="100%"
 style='border-collapse:collapse'&gt;
 &lt;tr&gt;
  &lt;td width="100%" valign=top style='width:100.0%;padding:0cm 5.4pt 0cm 5.4pt'&gt;
  &lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;a name=isume&gt;&lt;span lang=EN-GB&gt;Summary&lt;/span&gt;&lt;/a&gt;&lt;/h3&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Recommendation ITU-T K.82 defines the
  basic requirements and parameters of solid-state, self-restoring overcurrent
  protectors (OCPs) for the protection of telecommunication installations (for
  example, exchange equipment, access equipment, telecommunication lines and
  subscriber or customer equipment). &lt;/span&gt;&lt;/p&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;This Recommendation should be used for
  the harmonization of existing or future specifications issued by solid-state,
  self-restoring overcurrent protector manufacturers, telecommunication
  equipment manufacturers, administrations or network operators.&lt;/span&gt;&lt;/p&gt;
  &lt;/td&gt;
 &lt;/tr&gt;
&lt;/table&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB style='font-size:52.0pt'&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>mar, 29 nov 2010 10:15:48 GMT</pubDate><guid isPermaLink="false">T-REC-K.82-201005-I!!MSW-E</guid></item><item><title>[ K.82 (05/10) ] - Characteristics and ratings of solid-state, self-restoring overcurrent protectors for the protection of telecommunications installations</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.82-201005-I&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;table class=MsoNormalTable border=0 cellspacing=0 cellpadding=0 width="100%"
 style='border-collapse:collapse'&gt;
 &lt;tr&gt;
  &lt;td width="100%" valign=top style='width:100.0%;padding:0cm 5.4pt 0cm 5.4pt'&gt;
  &lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;a name=isume&gt;&lt;span lang=EN-GB&gt;Summary&lt;/span&gt;&lt;/a&gt;&lt;/h3&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Recommendation ITU-T K.82 defines the
  basic requirements and parameters of solid-state, self-restoring overcurrent
  protectors (OCPs) for the protection of telecommunication installations (for
  example, exchange equipment, access equipment, telecommunication lines and
  subscriber or customer equipment). &lt;/span&gt;&lt;/p&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;This Recommendation should be used for
  the harmonization of existing or future specifications issued by solid-state,
  self-restoring overcurrent protector manufacturers, telecommunication
  equipment manufacturers, administrations or network operators.&lt;/span&gt;&lt;/p&gt;
  &lt;/td&gt;
 &lt;/tr&gt;
&lt;/table&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB style='font-size:52.0pt'&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>mar, 29 nov 2010 10:15:48 GMT</pubDate><guid isPermaLink="false">T-REC-K.82-201005-I!!PDF-E</guid></item><item><title>[ K.12 (05/10) ] - Characteristics of gas discharge tubes for the protection of telecommunications installations</title><link>http://www.itu.int/rec/recommendation.asp?parent=T-REC-K.12-201005-I&amp;type=items</link><description>

&lt;div class=WordSection1&gt;

&lt;table class=MsoNormalTable border=0 cellspacing=0 cellpadding=0 width="100%"
 style='border-collapse:collapse'&gt;
 &lt;tr&gt;
  &lt;td width="100%" valign=top style='width:100.0%;padding:0cm 5.4pt 0cm 5.4pt'&gt;
  &lt;h3 style='margin-left:0cm;text-indent:0cm'&gt;&lt;a name=isume&gt;&lt;span lang=EN-GB&gt;Summary&lt;/span&gt;&lt;/a&gt;&lt;/h3&gt;
  &lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;Recommendation ITU-T K.12 defines the
  basic characteristics to be met by gas discharge tubes for the protection of
  exchange and outdoor equipment, subscriber or customer equipment and
  telecommunication lines from surges. It is intended to be used for the
  harmonization of existing or future specifications issued by gas discharge tube
  manufacturers, telecommunication equipment manufacturers, administrations or
  network operators.&lt;/span&gt;&lt;span lang=EN-GB&gt; &lt;/span&gt;&lt;/p&gt;
  &lt;/td&gt;
 &lt;/tr&gt;
&lt;/table&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB style='font-size:52.0pt'&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;p class=MsoNormal&gt;&lt;span lang=EN-GB&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;/div&gt;

</description><pubDate>ven, 11 nov 2010 15:02:41 GMT</pubDate><guid isPermaLink="false">T-REC-K.12-201005-I!!MSW-E</guid></item></channel></rss>

